INA212-Q1_15 Datasheet, PDF (1/28 Pages) Texas Instruments – Zero-Drift Series, Current-Shunt Monitors | |||
|
Product
Folder
Sample &
Buy
Technical
Documents
Tools &
Software
Support &
Community
INA212-Q1, INA213A-Q1, INA214-Q1
SBOS475E â MARCH 2009 â REVISED DECEMBER 2014
INA21x-Q1 Automotive-Grade Voltage Output, Low- or High-Side Measurement,
Bidirectional, Zero-Drift Series, Current-Shunt Monitors
1 Features
â¢1 Qualified for Automotive Applications
⢠Wide Common-Mode Range: â0.3 V to 26 V
⢠Offset Voltage: ±100 µV (Maximum)
(Enables Shunt Drops of 10-mV Full-Scale)
⢠Accuracy:
â ±1% Gain Error (Maximum over Temperature)
â 0.5-µV/°C Offset Drift (Maximum)
â 10-ppm/°C Gain Drift (Maximum)
⢠Choice of Gain
â INA212-Q1: 1000 V/V
â INA213A-Q1: 50 V/V
â INA214-Q1: 100 V/V
⢠Quiescent Current: 100 µA (Maximum)
⢠SC70 Package
2 Applications
⢠Body Control Module
⢠Valve Control
⢠Motor Control
⢠Electronic Stability Control
⢠Wireless Charging Transmitters
3 Description
The INA21x-Q1 devices are voltage-output, current-
shunt monitors (also called current-sense amplifiers)
that can sense drops across shunts at common-mode
voltages from â0.3 V to 26 V, independent of the
supply voltage. The INA212-Q1 offers a fixed gain of
1000 V/V, INA213A-Q1 offers a fixed gain of 50 V/V,
and the INA214-Q1 offers a fixed gain of 100 V/V.
The low offset of the zero-drift architecture enables
current sensing with maximum drops across the
shunt as low as 10-mV full-scale.
The devices operate from a single 2.7-V to 26-V
power supply, drawing a maximum of 100 µA of
supply current. They are specified over the operating
temperature range of â40°C to 125°C and are offered
in an SC70 package.
Device Information(1)
PART NUMBER
PACKAGE
GAIN (V/V)
INA212-Q1
1000
INA213A-Q1
SOT (6)
50
INA214-Q1
100
(1) For all available packages, see the orderable addendum at
the end of the datasheet.
Reference
Voltage
Supply
Simplified Schematic
RSHUNT
Load
REF
INA21x-Q1
OUT
GND
R1
R3 IN-
Output
2.7 V to 26 V
V+
CBYPASS
0.01 mF
to
0.1 mF
R2
SC70
IN+
R4
PRODUCT
INA212-Q1
INA213A-Q1
INA214-Q1
GAIN
1000
50
100
R3 and R4
1 kW
20 kW
10 kW
R1 and R2
1 MW
1 MW
1 MW
VOUT = (ILOAD ´ RSHUNT) Gain + VREF
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
|
▷ |