English
Language : 

INA210_17 Datasheet, PDF (1/44 Pages) Texas Instruments – Voltage Output, Low- or High-Side Measurement, Bidirectional, Zero-Drift Series, Current-Shunt Monitors
Product
Folder
Order
Now
Technical
Documents
Tools &
Software
Support &
Community
INA210, INA211, INA212, INA213, INA214, INA215
SBOS437J – MAY 2008 – REVISED FEBRUARY 2017
INA21x Voltage Output, Low- or High-Side Measurement, Bidirectional,
Zero-Drift Series, Current-Shunt Monitors
1 Features
•1 Wide Common-Mode Range: –0.3 V to 26 V
• Offset Voltage: ±35 μV (Maximum, INA210)
(Enables Shunt Drops of 10-mV Full-Scale)
• Accuracy:
– Gain Error (Maximum Over Temperature):
– ±0.5% (Version C)
– ±1% (Versions A and B)
– 0.5-µV/°C Offset Drift (Maximum)
– 10-ppm/°C Gain Drift (Maximum)
• Choice of Gains:
– INA210: 200 V/V
– INA211: 500 V/V
– INA212: 1000 V/V
– INA213: 50 V/V
– INA214: 100 V/V
– INA215: 75 V/V
• Quiescent Current: 100 μA (Maximum)
• SC70 and Thin UQFN Packages: All Models
2 Applications
• Notebook Computers
• Cell Phones
• Telecom Equipment
• Power Management
• Battery Chargers
3 Description
The INA21x are voltage-output, current-shunt
monitors (also called current-sense amplifiers) that
are commonly used for overcurrent protection,
precision-current measurement for system
optimization, or in closed-loop feedback circuits. This
series of devices can sense drops across shunts at
common-mode voltages from –0.3 V to 26 V,
independent of the supply voltage. Six fixed gains are
available: 50 V/V, 75 V/V, 100 V/V, 200 V/V, 500 V/V,
or 1000 V/V. The low offset of the zero-drift
architecture enables current sensing with maximum
drops across the shunt as low as 10-mV full-scale.
These devices operate from a single 2.7-V to 26-V
power supply, drawing a maximum of 100 µA of
supply current. All versions are specified over the
extended
operating
temperature
range
(–40°C to +125°C), and offered in SC70 and UQFN
packages.
Device Information(1)
PART NUMBER
PACKAGE
BODY SIZE (NOM)
INA21x
SC70 (6)
UQFN (10)
2.00 mm × 1.25 mm
1.80 mm × 1.40 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Reference
Voltage
Supply
Simplified Schematic
RSHUNT
Load
REF
GND
INA21x
OUT
R1
R3 IN-
Output
2.7 V to 26 V
V+
CBYPASS
0.01 mF
to
0.1 mF
R2
SC70
IN+
R4
PRODUCT
INA210
INA211
INA212
INA213
INA214
INA215
GAIN
200
500
1000
50
100
75
R3 and R4
5 kW
2 kW
1 kW
20 kW
10 kW
13.3 kW
R1 and R2
1 MW
1 MW
1 MW
1 MW
1 MW
1 MW
VOUT = (ILOAD ´ RSHUNT) Gain + VREF
Copyright © 2017, Texas Instruments Incorporated
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.