DS36C279_14 Datasheet, PDF (1/18 Pages) Texas Instruments – DS36C279 Low Power EIA-RS-485 Transceiver with Sleep Mode
DS36C279
www.ti.com
SNLS098B – JULY 2000 – REVISED APRIL 2013
DS36C279 Low Power EIA-RS-485 Transceiver with Sleep Mode
Check for Samples: DS36C279
FEATURES
1
• 100% RS-485 Compliant
– Specified RS-485 Device Interoperation
• Low Power CMOS Design: ICC 500 μA Max
• Automatic Sensing Sleep Mode
– Reduces ICC to 10 μA Maximum
• Built-in Power Up/Down Glitch-Free Circuitry
– Permits Live Transceiver
Intersection/Displacement
• SOIC Packages
• Industrial Temperature Range: −40°C to
+85°C
• On-Board Thermal Shutdown Circuitry
– Prevents Damage to the Device in the Event
of Excessive Power Dissipation
• Wide Common Mode Range: −7V to +12V
• Receive Open Input Fail-Safe(1)
• ¼ Unit Load (DS36C279): ≥ 128 Nodes
• ½ Unit Load (DS36C279T): ≥ 64 Nodes
• ESD (Human Body Model): ≥ 2 kV
• Drop-In Replacement for:
– LTC485 MAX485 DS75176 DS3695
(1) Non-terminated, open input only
DESCRIPTION
The DS36C279 is a low power differential bus/line
transceiver designed to meet the requirements of RS-
485 Standard for multipoint data transmission. In
addition it is compatible with TIA/EIA-422-B.
The sleep mode feature automatically puts the device
in a power saving mode when both the driver and
receiver are disabled.(2) The device is ideal for use in
power conscious applications where the device may
be disabled for extended periods of time.
The driver and receiver outputs feature TRI-STATE
capability. The driver outputs operate over the entire
common mode range of −7V to +12V. Bus contention
or fault situations that cause excessive power
dissipation within the device are handled by a thermal
shutdown circuit, which forces the driver outputs into
a high impedance state.
The receiver incorporates a fail safe circuit which
ensures a high output state when the inputs are left
open. (3)
The DS36C279T is fully specified over the industrial
temperature range (−40°C to +85°C).
(2) Device enters sleep mode if enable conditions are held > 600
ns
(3) Non-terminated, open input only
Connection and Logic Diagram
Figure 1. See Package Number D
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2000–2013, Texas Instruments Incorporated