English
Language : 

CD54ACT05_14 Datasheet, PDF (1/12 Pages) Texas Instruments – HEX INVERTERS
www.ti.com
FEATURES
• Inputs Are TTL-Voltage Compatible
• Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
• Fanout to 15 F Devices
• SCR-Latchup-Resistant CMOS Process and
Circuit Design
• Exceeds 2-kV ESD Protection Per
MIL-STD-883, Method 3015
CD54ACT05, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
CD54ACT05 . . . F PACKAGE
CD74ACT05 . . . E OR M PACKAGE
(TOP VIEW)
1A 1
1Y 2
2A 3
2Y 4
3A 5
3Y 6
GND 7
14 VCC
13 6A
12 6Y
11 5A
10 5Y
9 4A
8 4Y
DESCRIPTION/ORDERING INFORMATION
The 'ACT05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The
open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain
outputs to implement active-low wired-OR or active-high wired-AND functions.
TA
–55°C to 125°C
PDIP – E
SOIC – M
CDIP – F
ORDERING INFORMATION
PACKAGE (1)
ORDERABLE PART NUMBER
Tube of 25
CD74ACT05E
Tube of 50
CD74ACT05M
Reel of 2500
CD74ACT05M96
Reel of 1000
CD54ACT05F3A
TOP-SIDE MARKING
CD74ACT05E
ACT05M
CD54ACT05F3A
(1) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
FUNCTION TABLE
(EACH INVERTER)
INPUT
A
H
L
OUTPUT
Y
L
Z
A
Y
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2001–2007, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are
tested unless otherwise noted. On all other products, production