TLE202X-Q1 Datasheet, PDF (9/39 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS | |||
|
◁ |
Ä
TLE202xÄQ1, TLE202xAÄQ1
EXCALIBUR HIGHÄSPEED LOWÄPOWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS199A â JANUARY 2004 â REVISED APRIL 2004
TLE2024 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLE2024-Q1
TLE2024A-Q1
TAâ
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
1100
1300
850
µV
1050
αVIO
Temperature coefficient
of input offset voltage
Full range
2
2
µV/°C
Input offset voltage
long-term drift
(see Note 4)
VIC = 0,
RS = 50 â¦
25°C
0.005
0.005
µV/mo
IIO
Input offset current
25°C
Full range
0.6
6
10
0.5
6
nA
10
IIB
Input bias current
25°C
Full range
45 70
90
40 70
nA
90
VICR
Common-mode input
voltage range
RS = 50 â¦
0 â0.3
0 â0.3
25°C
to
to
to
to
3.5
4
3.5
4
V
0
0
Full range
to
to
3.2
3.2
VOH
VOL
High-level output voltage
Low-level output voltage
RL = 10 kâ¦
25°C
3.9 4.2
3.9 4.2
V
Full range 3.7
3.7
25°C
Full range
0.7 0.8
0.95
0.7 0.8
V
0.95
AVD
Large-signal differential
voltage amplification
25°C
VO = 1.4 V to 4 V, RL = 10 k⦠Full range
0.2
0.1
1.5
0.3 1.5
0.1
V/µV
Common-mode rejection
25°C
80 90
CMRR ratio
VIC = VICRmin, RS = 50 ⦠Full range
80
82 92
dB
82
kSVR
Supply-voltage rejection
ratio (âVCC± /âVIO)
VCC ± = ±2.5 V to ±15 V
25°C
Full range
98 112
93
100 115
95
dB
ICC
Supply current
25°C
Full range
800 1200
1200
800 1200
µA
1200
Supply current change VO = 0,
No load
âICC over operating
Full range
50
temperature range
50
µA
â Full range is â40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265