How to Set Dead Time
The primary function of the dead-time control is to control the minimum off time of the output of the TL594. The
dead-time control input provides control from 5% to 100% dead time. The TL594 can be tailored to the specific
power transistor switches that are used, to ensure that the output transistors never experience a common
on-time. The bias circuit for the basic function is shown in Figure 7.
VREF
R1
TD = RTCT(0.05 + 0.35R2)
R2 in kW
Dead-Time Control In
R1 + R2 = 5 kW
R2
Figure 7. Setting Dead Time
Submit Documentation Feedback
9