English
Language : 

ISO7420FE Datasheet, PDF (9/19 Pages) Texas Instruments – Low-Power Dual Channel Digital Isolators
ISO7420E, ISO7420FE
ISO7421E, ISO7421FE
www.ti.com
SLLSE45B – DECEMBER 2010 – REVISED JANUARY 2011
DEVICE INFORMATION
IEC INSULATION AND SAFETY-RELATED SPECIFICATIONS FOR THE D-8 PACKAGE
over recommended operating conditions (unless otherwise noted)
L(I01)
L(I02)
CTI
RIO
CIO
CI
PARAMETER
Minimum air gap (clearance)
Minimum external tracking
(creepage)
Tracking resistance (comparative
tracking index)
Minimum internal gap (internal
clearance)
Isolation resistance, input to
output (1)
Barrier capacitance, input to
output (1)
Input capacitance(2)
TEST CONDITIONS
Shortest terminal-to-terminal distance through air
Shortest terminal-to-terminal distance across the
package surface
DIN IEC 60112 / VDE 0303 Part 1
Distance through the insulation
VIO = 500 V, TA < 100°C
VIO = 500 V, 100°C ≤ TA ≤ max
VIO = 0.4 sin (2pft), f = 1 MHz
VI = VCC/2 + 0.4 sin (2pft), f = 1 MHz, VCC = 5 V
(1) All pins on each side of the barrier tied together creating a two-terminal device.
(2) Measured from input pin to ground.
MIN TYP MAX UNIT
4.8
mm
4.3
mm
>400
V
0.014
mm
>1012
Ω
>1011
Ω
1
pF
1
pF
NOTE
Creepage and clearance requirements should be applied according to the specific
equipment isolation standards of an application. Care should be taken to maintain the
creepage and clearance distance of a board design to ensure that the mounting pads of
the isolator on the printed-circuit board do not reduce this distance.
Creepage and clearance on a printed-circuit board become equal according to the
measurement techniques shown in the Isolation Glossary. Techniques such as inserting
grooves and/or ribs on a printed circuit board are used to help increase these
specifications.
INSULATION CHARACTERISTICS(3)
over recommended operating conditions (unless otherwise noted)
VIORM
VPR
VIOTM
VISO
RS
PARAMETER
Maximum working insulation voltage
Input-to-output test voltage per IEC
60747-5-2
Transient overvoltage per IEC 60747-5-2
Isolation voltage per UL
Insulation resistance
Pollution degree
TEST CONDITIONS
Method a, After environmental tests subgroup 1,
VPR = VIORM x 1.6, t = 10 s,
Partial Discharge < 5 pC
Method b1,
VPR = VIORM x 1.875, t = 1 s (100% Production test)
Partial discharge < 5 pC
After Input/Output safety test subgroup 2/3,
VPR = VIORM x 1.2, t = 10 s,
Partial discharge < 5 pC
VTEST = VIOTM
t = 60 sec (qualification)
t= 1 sec (100% production)
VTEST = VISO, t = 60 sec (qualification)
VTEST = 1.2 x VISO, t = 1 sec (100% production)
VIO = 500 V at TS
(3) Climatic Classification 40/125/21
SPECIFICATION
560
896
1050
672
4000
2500
3000
>109
2
UNIT
VPEAK
VPEAK
VPEAK
VRMS
Ω
Copyright © 2010–2011, Texas Instruments Incorporated
Submit Documentation Feedback
9