www.ti.com
DATA COMMANDS
bq27520-G4
SLUSB20 – NOVEMBER 2012
STANDARD DATA COMMANDS
Thebq27520-G4 uses a series of 2-byte standard commands to enable system reading and writing of battery
information. Each standard command has an associated command-code pair, as indicated in Table 2. Because
each command consists of two bytes of data, two consecutive I2C transmissions must be executed both to
initiate the command function, and to read or write the corresponding two bytes of data. Additional details are
found in the bq27520-G4 Technical Reference Manual.
NAME
Control( )
AtRate( )
AtRateTimeToEmpty( )
Temperature( )
Voltage( )
Flags( )
NominalAvailableCapacity( )
FullAvailableCapacity( )
RemainingCapacity( )
FullChargeCapacity( )
AverageCurrent( )
TimeToEmpty( )
StandbyCurrent( )
StandbyTimeToEmpty( )
StateOfHealth( )
CycleCount( )
StateOfCharge( )
InstantaneousCurrent( )
InternalTemperature( )
ResistanceScale( )
OperationConfiguration( )
DesignCapacity( )
Table 2. Standard Commands
CNTL
TEMP
VOLT
FLAGS
NAC
FAC
RM
FCC
TTE
SOH
SOC
Op Config
COMMAND CODE
0x00 / 0x01
0x02 / 0x03
0x04 / 0x05
0x06 / 0x07
0x08 / 0x09
0x0a / 0x0b
0x0c / 0x0d
0x0e / 0x0f
0x10 / 0x11
0x12 / 0x13
0x14 / 0x15
0x16 / 0x17
0x18 / 0x19
0x1a / 0x1b
0x1c / 0x1d
0x1e / 0x1f
0x20 / 0x21
0x22 / 0x23
0x28 / 0x29
0x2a / 0x2b
0x2c / 0x2d
0x2e / 0x2f
UNITS
N/A
mA
Minutes
0.1 K
mV
N/A
mAh
mAh
mAh
mAh
mA
Minutes
mA
Minutes
% / num
num
%
mA
0.1 K
N/A
mAh
SEALED
ACCESS
R/W
R/W
R
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Copyright © 2012, Texas Instruments Incorporated