TL431B Datasheet, PDF (8/40 Pages) Texas Instruments – ADJUSTABLE PRECISION SHUNT REGULATORS | |||
|
◁ |
TL431, TL431A, TL431B, TL432, TL432A, TL432B
ADJUSTABLE PRECISION SHUNT REGULATORS
SLVS543A â AUGUST 2004 â REVISED AUGUST 2004
equivalent schematicâ
CATHODE
800 â¦
REF
2.4 kâ¦
3.28 kâ¦
4 kâ¦
7.2 kâ¦
20 pF
800 â¦
20 pF
150 â¦
10 kâ¦
ANODE
â All component values are nominal.
800 â¦
1 kâ¦
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)â¡
Cathode voltage, VKA (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 V
Continuous cathode current range, IKA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â100 mA to 150 mA
Reference input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â50 µA to 10 mA
Operating virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â65°C to 150°C
â¡ Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: Voltage values are with respect to the ANODE terminal, unless otherwise noted.
package thermal data (see Note 2)
PACKAGE
PDIP (P)
BOARD
High K, JESD 51-7
θJC
57°C/W
θJA
85°C/W
SOIC (D)
High K, JESD 51-7
39°C/W
97°C/W
SOP (PS)
High K, JESD 51-7
46°C/W
95°C/W
SOT-89 (PK)
High K, JESD 51-7
9°C/W
52°C/W
SOT-23-5 (DBV)
High K, JESD 51-7
131°C/W
206°C/W
SOT-23-3 (DBZ)
High K, JESD 51-7
TBD
TBD
TO-92 (LP)
High K, JESD 51-7
55°C/W
140°C/W
TSSOP (PW)
High K, JESD 51-7
65°C/W
149°C/W
NOTE 2: Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) â TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
8