English
Language : 

SN74LVCC4245A_08 Datasheet, PDF (8/17 Pages) Texas Instruments – OCTAL DUAL-SUPPLY BUS TRANSCEIVER WITH CONFIGURABLE OUTPUT VOLTAGE AND 3-STATE OUTPUTS
SN74LVCC4245A
OCTAL DUAL-SUPPLY BUS TRANSCEIVER
WITH CONFIGURABLE OUTPUT VOLTAGE AND 3-STATE OUTPUTS
SCAS584M – NOVEMBER 1996 – REVISED MARCH 2005
PARAMETER MEASUREMENT INFORMATION FOR B TO A
VCCA = 4.5 V to 5.5 V AND VCCB = 2.7 V TO 3.6 V
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω S1
500 Ω
2 × VCCA
Open
GND
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
S1
Open
2 × VCCA
GND
www.ti.com
LOAD CIRCUIT
Input
tw
3V
1.5 V
1.5 V
0V
VOLTAGE WAVEFORMS
PULSE DURATION
Input
Output
3V
1.5 V
1.5 V
0V
tPLH
tPHL
1.5 V
VOH
1.5 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
NONINVERTING OUTPUTS
Output
Control
3V
1.5 V
1.5 V
0V
tPZL
Output
Waveform 1
S1 at 2 × VCCA
(see Note B)
tPZH
Output
Waveform 2
S1 at GND
(see Note B)
1.5 V
1.5 V
tPLZ
VCCA
VOL + 0.3 V VOL
tPHZ
VOH
VOH - 0.3 V
≈0 V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
LOW- AND HIGH-LEVEL ENABLING
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. All parameters and waveforms are not applicable to all devices.
Figure 3. Load Circuit and Voltage Waveforms
8