DC Electrical Specifications (Continued)
PARAMETER
TEST CONDITIONS
AMBIENT TEMPERATURE, TA
25oC
-40oC - 85oC -55oC - 125oC
VIS
VI
VEE VCC
(V)
(V)
(V) (V) MIN TYP MAX MIN MAX MIN MAX UNITS
HCT TYPES
High Level Input Voltage,
VIH
Low Level Input Voltage,
VIL
On Resistance, rON
IO = 1mA, (Figure 15)
VCC or VEE
4.5 to 2
-
-
2
-
2
-
V
5.5
4.5 to -
5.5
-
0.8
-
0.8
-
0.8
V
VIL or
0
4.5
-
70 160
-
200
-
240 Ω
VIH
-
-
-
-
-
-
-
-
-
Ω
-4.5 4.5
-
40 120
-
150
-
180 Ω
VCC to VEE
0 4.5
-
90 180
-
225
-
270 Ω
-
-
-
-
-
-
-
-
-
Ω
-4.5 4.5
-
45 130
-
162
-
195 Ω
Maximum On Resistance
Between any Two
Channels, ∆rON
0 4.5
-
10
-
-
-
-
-
Ω
-
-
-
-
-
-
-
-
-
Ω
-4.5 4.5
-
5
-
-
-
-
-
Ω
Switch On/Off Leakage For Switch Off:
VIL or
Current, IIZ
When VIS = VCC, VIH
1 and 2 Channels
VOS = VEE;
When VIS = VEE,
0
6
-
4053
VOS = VCC
-5
5
-
For Switch On:
4 Channels
All Applicable
0
6
-
4052
8 Channels
Combinations of
VIS and VOS
Voltage Levels
-5
5
-
0
6
-
-
±0.1
-
±1
-
±1
µA
-
±0.1
-
±1
-
±1
µA
-
±0.1
-
±1
-
±1
µA
-
±0.2
-
±2
-
±2
µA
-
±0.2
-
±2
-
±2
µA
4051
-5
5
-
-
±0.4
-
±4
-
±4
µA
Control Input Leakage -
Current, IIL
(Note 4) -
5.5
-
-
±0.1
-
±1
-
±1
µA
Quiescent Device
Current, ICC
IO = 0
When VIS = VEE, VCC or 0
5.5
-
VOS = VCC
GND
When VIS = VCC,
VOS = VEE
-4.5 5.5
-
-
8
-
80
-
160 µA
-
16
-
160
-
320 µA
Additional Quiescent
Device Current
Per Input Pin: 1 Unit
Load
∆ICC
(Note 5)
VCC -
2.1
4.5 to -
100 360
-
450
-
490 µA
5.5
NOTES:
4. Any voltage between VCC and GND.
5. For dual supply systems theoretical worst case (VI = 2.4V, VCC = 5.5V) specification is 1.8mA.
HCT Input Loading Table
TYPE
INPUT
UNIT LOADS
(NOTE)
4051, 4053
All
0.5
4052
All
0.4
NOTE: Unit
e.g., 360mA
lmoaadx.isat∆2IC5CoCli.mit
specified
in
DC
Specifications
table,
8