English
Language : 

TL384XB Datasheet, PDF (7/21 Pages) Texas Instruments – HIGH-PERFORMANCE CURRENT-MODE PWM CONTROLLERS
www.ti.com
TL284xB, TL384xB
HIGH-PERFORMANCE CURRENT-MODE PWM CONTROLLERS
SLVS610A – AUGUST 2006 – REVISED SEPTEMBER 2006
Output Section Electrical Characteristics
VCC = 15 V(1), RT = 10 kΩ, CT = 3.3 nF, over recommended operating free-air temperature range (unless otherwise specified)
PARAMETER
TEST CONDITIONS
TL284xB
MIN TYP(2)
MAX
TL384xB
MIN TYP(2)
UNIT
MAX
High-level output voltage
Low-level output voltage
Rise time
Fall time
UVLO saturation
IOH = –20 mA
IOH = –200 mA
IOL = 20 mA
IOL = 200 mA
CL = 1 nF, TJ = 25°C
CL = 1 nF, TJ = 25°C
VCC = 5 V, IOL = 1 mA
13
13.5
12
13.5
0.1
0.4
1.5
2.2
50
150
50
150
0.7
1.2
13
13.5
12
13.5
0.1
1.5
50
50
0.7
V
0.4
V
2.2
150 ns
150 ns
1.2 V
(1) Adjust VCC above the start threshold before setting it to 15 V.
(2) All typical values are at TJ = 25°C.
Undervoltage-Lockout Section Electrical Characteristics
VCC = 15 V(1), RT = 10 kΩ, CT = 3.3 nF, over recommended operating free-air temperature range (unless otherwise specified)
PARAMETER
TEST CONDITIONS
TL284xB
MIN TYP(2)
MAX
TL384xB
MIN TYP(2)
UNIT
MAX
Start threshold voltage
TLx842B, TLx844B
TLx843B, TLx845B
15
16
7.8
8.4
17
14.5
9
7.8
16
17.5
V
8.4
9
Minimum operating voltage
after start-up
TLx842B, TLx844B
TLx843B, TLx845B
9
10
11
8.5
10
11.5
V
7
7.6
8.2
7
7.6
8.2
(1) Adjust VCC above the start threshold before setting it to 15 V.
(2) All typical values are at TJ = 25°C.
Pulse-Width Modulator Section Electrical Characteristics
VCC = 15 V(1), RT = 10 kΩ, CT = 3.3 nF, over recommended operating free-air temperature range (unless otherwise specified)
PARAMETER
TEST CONDITIONS
TL284xB
MIN TYP(2)
MAX
TL384xB
MIN TYP(2)
UNIT
MAX
Maximum duty cycle
TL3842B, TL3843B
TL3844B, TL3845B
94
96
100
94
96
100
%
47
48
50
47
48
50
Minimum duty cycle
0
0%
(1) Adjust VCC above the start threshold before setting it to 15 V.
(2) All typical values are at TJ = 25°C.
Supply Voltage Electrical Characteristics
VCC = 15 V(1), RT = 10 kΩ, CT = 3.3 nF, over recommended operating free-air temperature range (unless otherwise specified)
PARAMETER
TEST CONDITIONS
TL284xB
MIN TYP(2)
MAX
TL384xB
MIN TYP(2)
UNIT
MAX
Start-up current
0.3
0.5
0.3
0.5 mA
Operating supply current
Limiting voltage
VFB and ISENSE at 0 V
ICC = 25 mA
11
17
11
17 mA
30
34
30
34
V
(1) Adjust VCC above the start threshold before setting it to 15 V.
(2) All typical values are at TJ = 25°C.
Submit Documentation Feedback
7