English
Language : 

TL061_10 Datasheet, PDF (7/42 Pages) Texas Instruments – LOW-POWER JFET-INPUT OPERATIONAL AMPLIFIERS
TL061, TL061A, TL061B, TL062, TL062A
TL062B, TL064, TL064A, TL064B
LOWĆPOWER JFETĆINPUT OPERATIONAL AMPLIFIERS
SLOS078J − NOVEMBER 1978 − REVISED SEPTEMBER 2004
electrical characteristics, VCC± = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS†
TL061BC
TL062BC
TL064BC
TL061I
TL062I
TL064I
UNIT
MIN TYP MAX MIN TYP MAX
VIO
αVIO
IIO
IIB
VICR
Input offset voltage
Temperature coefficient of
input offset voltage
Input offset current
Input bias current‡
Common-mode
input voltage range
VO = 0,
RS = 50 Ω
TA = 25°C
TA = Full range
VO = 0, RS = 50 Ω,
TA = Full range
VO = 0
TA = 25°C
TA = Full range
VO = 0
TA = 25°C
TA = Full range
TA = 25°C
2
3
5
3
6
mV
9
10
10
µV/°C
5 100
5 100 pA
3
10 nA
30 200
30 200 pA
7
20 nA
−12
−12
±11
to
±11
to
V
15
15
VOM
AVD
B1
ri
CMRR
Maximum peak output
voltage swing
Large-signal differential
voltage amplification
Unity-gain bandwidth
Input resistance
Common-mode
rejection ratio
RL = 10 kΩ, TA = 25°C
RL ≥ 10 kΩ, TA = Full range
VO = ± 10 V, TA = 25°C
RL ≥ 10 kΩ TA = Full range
RL = 10 kΩ, TA = 25°C
TA = 25°C
VIC = VICRmin, VO = 0,
RS = 50 Ω, TA = 25°C
±10 ±13.5
±10
4
6
4
1
1012
80
86
±10 ±13.5
±10
4
6
4
1
1012
80
86
V
V/mV
MHz
Ω
dB
kSVR
PD
Supply-voltage rejection
ratio
(∆VCC±/∆VIO)
Total power dissipation
(each amplifier)
VCC = ± 9 V to ± 15 V,
VO = 0, RS = 50 Ω,
TA = 25°C
VO = 0,
No load
TA = 25°C,
80
95
80
95
dB
6 7.5
6 7.5 mW
Supply current
ICC
(each amplifier)
VO = 0,
No load
TA = 25°C,
200 250
200 250 µA
VO1/VO2 Crosstalk attenuation
AVD = 100, TA = 25°C
120
120
dB
† All characteristics are measured under open-loop conditions with zero common-mode input voltage, unless otherwise specified. Full range for
TA is 0°C to 70°C for TL06_C, TL06_AC, and TL06_BC and −40°C to 85°C for TL06_I.
‡ Input bias currents of an FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive, as shown in
Figure 15. Pulse techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7