English
Language : 

SN54ABT2952A Datasheet, PDF (7/17 Pages) Texas Instruments – OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
From Output
Under Test
CL = 50 pF
(see Note A)
SN54ABT2952A, SN74ABT2952A
OCTAL BUS TRANSCEIVERS AND REGISTERS
WITH 3-STATE OUTPUTS
SCBS203D – AUGUST 1992 – REVISED JANUARY 1998
PARAMETER MEASUREMENT INFORMATION
500 Ω
500 Ω
7V
S1
Open
GND
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
S1
Open
7V
Open
Input
LOAD CIRCUIT
tw
1.5 V
3V
1.5 V
0V
VOLTAGE WAVEFORMS
PULSE DURATION
Timing Input
Data Input
3V
1.5 V
0V
tsu
th
3V
1.5 V
1.5 V
0V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
Input
1.5 V
3V
1.5 V
0V
tPLH
Output
1.5 V
tPHL
VOH
1.5 V
VOL
tPHL
tPLH
Output
1.5 V
1.5 V
VOH
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
INVERTING AND NONINVERTING OUTPUTS
Output
Control
Output
Waveform 1
S1 at 7 V
(see Note B)
Output
Waveform 2
S1 at Open
(see Note B)
tPZL
tPZH
1.5 V
tPLZ
1.5 V
tPHZ
1.5 V
3V
1.5 V
0V
3.5 V
VOL + 0.3 V VOL
VOH – 0.3 V VOH
≈0 V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
LOW- AND HIGH-LEVEL ENABLING
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
D. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7