English
Language : 

PTB48510 Datasheet, PDF (7/13 Pages) Texas Instruments – Dual Complementary-Output DC/DC Converter for DSL
PTB48510C
Dual Complementary-Output
DC/DC Converter for DSL
SLTS219C - FEBRUARY 2004 - REVISED OCTOBER 2004
Specifications (Unless otherwise stated, Ta =25°C, Vin =48 V, Cin =0 µF, ±Co =0 µF, |+Io | = |–Io |, and |±Io | =0.5 |±Io |max)
PTB48510C
Characteristic
Symbol
Conditions
Min
Typ
Max
Units
Output Power
Output Current
Output Load Imbalance
Output Voltage
Temperature Variation
Line Regulation
Load Regulation
Efficiency
Vo Ripple (pk-pk)
Transient Response
Over Current Threshold
Po
|±Io |
|+Io | – |–Io |
|±Vo |
∆Regtemp
∆Regline
∆Regload
η
±Vr
ttr
∆Vtr
Iotrip
Total output power from ±Vo
Over Vin range, |+Io | – |–Io | ≤ 0.1 A
|+Io | ≥0.1 A, |–Io | ≥ 0.1 A
Inlcudes set-point, line, |+Io | – |–Io | ≤ 0.1 A
–40 ≤Ta ≤+85°C
–40 ≤Ta ≤ +85°C, |±Io | =0.1 A
±Vo
Over Vin range, balanced load
±Vo
Over ±Io range, balanced load
±Vo
|±Io| =|±Io (max)|
20 MHz bandwidth,
Co =10 µF tantalum capacitor
0.1 A/µs load step, 50% to 75% ±Iomax
|±Vo | over/undershoot
Vin =36 V
reset followed by auto-recovery
0
0
0
14.5 (2)
—
—
—
—
—
—
—
2.45
—
—
—
15
±1
±0.05
±0.1
90
50
30
±1
3
66 (1)
2.2 (2)
1 (3)
15.5 (2)
—
±0.5
±1
—
100 (4)
—
—
3.85
W
A
A
V
%Vo
%Vo
%Vo
%
mVpp
µs
%Vo
A
Short Circuit Current
Continuous over-current trip,
|+Io | = |–Io |
|±Io |pk
—
4.5
—
A
Duty
—
10
—
%
Output Voltage Adjust Range
Switching Frequency
Under-Voltage Lockout
On/Off Enable (pin 3)
Input High Voltage
Input Low Voltage
Input Low Current
|±Vo | adj
ƒs
Vinon
Vinoff
VIH
VIL
IIL
|+Vo | and |–Vo | adjust simulataneously
Over Vin and Io ranges
Vin increasing
Vin decreasing
Referenced to –Vin (pin 4)
7.2
—
16.7
V
440
480 (5)
520
kHz
—
33
—
V
—
32
—
+3.6
—
–0.2
—
—
—
+75 (6)
V
+0.8
–1
mA
Standby Input Current
Start-up Time
Internal Input Capacitance
External Output Capacitance
Reliability
Iin standby
pin 3 open circuit
—
2
ton
|±Io | =1 A, |±Vo | rising 0 to 0.95 |±Vo | typ
6
12
Cin
—
3
±Co
Capacitance from either output to COM (pin 6)
0
—
MTBF
Per Bellcore TR-332
50% stress, Ta =40°C, gnd benign
2.8
—
—
18
—
3,000 (7)
—
mA
ms
µF
µF
106 Hrs
Notes: (1) See Safe Operating Area curves or contact the factory for the appropriate derating.
(2) Under balanced load conditions, load current flowing out of +Vo is balanced to within ±0.1 A of that flowing into –Vo.
(3) A load imbalance is the difference in current flowing from +Vo to –Vo. The module can operate with a higher imbalance but with reduced specifications.
(4) Output voltage ripple is measured with a 10 µF tantalum capacitor connected from +Vo (pin 5) or –Vo (pin 8), to COM (pin 6).
(5) This is the free-running frequency. The module can be made to synchronize with the PTB48500 when both modules are used together in a system.
(6) The On/Off Enable (pin 3) has an internal pull-up and may be controlled with an open-collector (or open-drain) transistor. The input is diode protected
and may be connected to +Vin. The open-circuit voltage is 5 V max. If it is left open circuit the converter will operate when input power is applied.
(7) Electrolytic capacitors with very low equivalent series resistance (ESR) may induce instability when used on the output. Consult the factory before using
capacitors with organic, or polymer-aluminum type electrolytes.
For technical support and further information visit http://power.ti.com