PGA309_11 Datasheet, PDF (7/24 Pages) Texas Instruments – Voltage Output Programmable Sensor Conditioner | |||
|
◁ |
PGA309
www.ti.com
SBOS292C â DECEMBER 2003 â REVISED JANUARY 2011
ELECTRICAL CHARACTERISTICS (continued)
Boldface limits apply over the specified temperature range, TA = â40°C to +125°C.
At TA = +25°C, VSA= VSD = +5V (VSA = VSUPPLY ANALOG, VSD = VSUPPLY DIGITAL; VSA must equal VSD), GNDD = GNDA = 0, and VREF
= REFIN/REFOUT = +5V, unless otherwise noted.
PGA309
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
Linearization Adjust and Excitation Voltage (VEXC)
Range 0
Register 3, bit D11 = 0
xx Linearization DAC Range
xx Linearization DAC Resolution
With respect to VFB
±127 steps, 7-bit + sign
â0.166 to +0.166
1.307
V/V
mV/V
xx VEXC Gain
xx Gain Error Drift
With respect to VREF
0.83
V/V
25
ppm/°C
Range 1
Register 3, bit D11 = 1
xx Linearization DAC Range
xx Linearization DAC Resolution
With respect to VFB
±127 steps, 7-bit + sign
â0.124 to +0.124
0.9764
V/V
mV/V
xx VEXC Gain
xx Gain Error Drift
With respect to VREF
0.52
V/V
25
ppm/°C
VEXC Range Upper Limit
IEXC SHORT
Digital Interface
IEXC = 5mA
Short-circuit VEXC output current
VSA â0.5
V
50
mA
Two-Wire Compatible
Bus speed
1
400
kHz
One-Wire
Serial speed baud rate
4.8K
38.4K
Bits/s
Maximum Lookup Table Size(7)
17 x 3 x 16
Bits
Two-Wire Data Rate
PGA309 to EEPROM (SCL frequency)
65
kHz
Logic Levels
Input Levels (SDA, SCL, PRG, TEST)
Input Levels (SDA, SCL, PRG, TEST)
Input Levels (SDA, SCL)
Pull-Up Current Source (SDA, SCL)
Low
High
Hysteresis
0.2 ⢠VSD
V
0.7 ⢠VSD
V
0.1 ⢠VSD
V
55
85
125
mA
Pull-Down Current Source (TEST)
15
25
40
mA
Output LOW Level (SDA, SCL, PRG)
Power Supply
Open drain, ISINK = 5mA
0.4
V
VSA, VSD
ISA + ISD, Quiescent Current
Power-On Reset (POR)
VSA = VSD = +5V, without bridge load
2.7
5.5
V
1.2
1.6
mA
Power-Up Threshold
Power-Down Threshold
Temperature Range
VS rising
VS falling
2.2
2.7
V
1.7
V
Specified Performance Range
â40
+125
°C
Operational-Degraded Performance Range
â55
+150
°C
(7) Lookup table allows multislope compensation over temperature. Lookup table has access to 17 calibration points consisting of three
adjustment values (Tx, Temperature, ZMx, Zero DAC, GMx, Gain DAC) that are stored in 16-bit data format (17x3x16 = Lookup table
size).
Copyright © 2003â2011, Texas Instruments Incorporated
Product Folder Link(s): PGA309
Submit Documentation Feedback
7
|
▷ |