English
Language : 

TPS5103 Datasheet, PDF (6/37 Pages) Texas Instruments – MULTIPLE MODE SYNCHRONOUS DC/DC CONTROLLER
TPS5103
MULTIPLE MODE SYNCHRONOUS DC/DC CONTROLLER
SLVS240 – SEPTEMBER 1999
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 27 V
Input voltage, VI, INV, CT, RT, PWM/SKIP, SOFTSTART, COMP . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V
Input voltage, VREG5V_IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6 V
Input voltage, STBY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 15 V
Input voltage, TRIP, VCC_SENSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 27 V
Output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A
Low level output voltage, VOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 27 V
High level output voltage, VOH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 32 V
Reference voltage, Vref . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 3 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. See Dissipation Rating Table for free-air temperature range above 25°C.
PACKAGE
DB
DISSIPATION RATING TABLE
TA ≤ 25°C
POWER RATING
801 mW
DERATING FACTOR
ABOVE TA = 25°C
6.408mW/°C
TA = 85°C
POWER RATING
416 mW
recommended operating conditions
VCC Supply voltage
INV, CT, RT, COMP, PWM_SKIP, SOFTSTART
VI
Input voltage
VREG5V_IN
STBY
RT‡
CT‡
Oscillator frequency
f
TRIP, VCC_SENCE
Timing register
Timing capacitor
Frequency
TA
Operating temperature range
‡ Not a JEDEC symbol.
MIN NOM MAX UNIT
4.5
25 V
6
5.5
V
12
25
82
kΩ
100
pF
200
kHz
– 40
85 °C
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265