I2C INTERFACE TIMING REQUIREMENTS
VCCB = 2.7 V to 5.5 V, GND = 0 V, TA = –40°C to 85°C (unless otherwise noted)(1)(2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
tPLZ Propagation delay
SDAB, SCLB(4)
(see Figure 5)
SDAA, SCLA(5)
(see Figure 4)
SDAA, SCLA(4)
(see Figure 5)
SDAB, SCLB(5)
(see Figure 4)
tPZL Propagation delay
SDAB, SCLB
SDAA, SCLA(5)
(see Figure 4)
SDAA, SCLA
SDAB, SCLB(5)
(see Figure 4)
VCCA ≤ 2.7 V
(see Figure 3)
VCCA ≥ 3 V
(see Figure 3)
B side to A side
tTLH Transition time
80%
20%
VCCA ≤ 2.7 V
(see Figure 4)
VCCA ≥ 3 V
(see Figure 4)
A side to B side
(see Figure 3)
B side to A side
tTHL Transition time
80%
20%
VCCA ≤ 2.7 V
(see Figure 4)
VCCA ≥ 3 V
(see Figure 4)
A side to B side
(see Figure 3)
www.ti.com
MIN TYP(3) MAX UNIT
80
141 250
ns
25
74 110
30
76(6) 110
10
86 230 ns
60
107 230
10
12 15
40
42 45 ns
110
125 140
1
52(6) 105
20
67 175 ns
30
48 90
(1) Times are specified with loads of 1.35-kΩ pullup resistance and 50-pF load capacitance on the B side and 167-Ω pullup and 57-pF load
capacitance on the A side. Different load resistance and capacitance alter the RC time constant, thereby changing the propagation delay
and transition times.
(2) Pullup voltages are VCCA on the A side and VCCB on the B side.
(3) Typical values were measured with VCCA = VCCB = 3.3 V at TA = 25°C, unless otherwise noted.
(4) The tPLH delay data from B to A side is measured at 0.4 V on the B side to 0.5 VCCA on the A side when VCCA is less than 2 V, and
1.5 V on the A side if VCCA is greater than 2 V.
(5) The proportional delay data from A to B side is measured at 0.3 VCCA on the A side to 1.5 V on the B side.
(6) Typical value measured with VCCA = 2.7 V at TA = 25°C