English
Language : 

BQ20Z40 Datasheet, PDF (6/18 Pages) Texas Instruments – SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK™ TECHNOLOGY FOR USE WITH THE bq29330
bq20z40
SLUS801A – FEBRUARY 2009 – REVISED MARCH 2009................................................................................................................................................ www.ti.com
DATA FLASH MEMORY CHARACTERISTICS
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
tDR
Data retention
Flash programming write-cycles
t(WORDPROG) Word programming time
I(DDdPROG) Flash-write supply current
See (1)
See (1)
See (1)
See (1)
TEST CONDITIONS
(1) Specified by design. Not production tested.
MIN
10
20,000
TYP MAX UNIT
Years
Cycles
2 ms
5
10 mA
SMBus TIMING SPECIFICATIONS
VCC = 2.4 V to 2.6 V, TA = –40°C to 85°C (unless otherwise noted)
fSMB
fMAS
tBUF
tHD:STA
tSU:STA
tSU:STO
PARAMETER
SMBus operating frequency
SMBus master clock frequency
Bus free time between start and stop
Hold time after (repeated) start
Repeated start setup time
Stop setup time
tHD:DAT
Data hold time
tSU:DAT
tTIMEOUT
tLOW
tHIGH
tLOW:SEXT
tLOW:MEXT
tF
tR
Data setup time
Error signal/detect
Clock low period
Clock high period
Cumulative clock low slave extend time
Cumulative clock low master extend time
Clock/data fall time
Clock/data rise time
TEST CONDITIONS
Slave mode, SMBC 50% duty cycle
Master mode, no clock low slave extend
Receive mode
Transmit mode
See (1)
See (2)
See (3)
See (4)
(VILMAX – 0.15 V) to (VIHMIN + 0.15 V)
0.9 VCC to (VILMAX – 0.15 V)
MIN TYP MAX UNIT
10
51.2
100
kHz
4.7
4
µs
4.7
4
0
300
ns
250
25
35 ms
4.7
µs
4
50
25
ms
10
300
ns
1000
(1) The bq20z40 times out when any clock low exceeds tTIMEOUT.
(2) tHIGH:MAX. is minimum bus idle time. SMBC = 1 for t > 50 µs causes reset of any transaction involving the bq20z40 that is in progress.
(3) tLOW:SEXT is the cumulative time a slave device is allowed to extend the clock cycles in one message from initial start to the stop.
(4) tLOW:MEXT is the cumulative time a master device is allowed to extend the clock cycles in one message from initial start to the stop.
6
Submit Documentation Feedback
Product Folder Link(s) :bq20z40
Copyright © 2009, Texas Instruments Incorporated