English
Language : 

TS12A4516_101 Datasheet, PDF (5/15 Pages) Texas Instruments – DUAL SUPPLY, LOW ON-STATE RESISTANCE SPST CMOS ANALOG SWITCHES
TS12A4516, TS12A4517
www.ti.com ................................................................................................................................................. SCDS236B – DECEMBER 2006 – REVISED APRIL 2009
Electrical Characteristics for ±1.8-V Supply(1)
V+ = 1.65 V to 1.95 V, V– = –1.65 V to –1.95 V, TA = –40°C to 85°C (unless otherwise noted)
PARAMETER
Analog Switch
SYMBOL
TEST CONDITIONS
TA
MIN
Analog signal range
VCOM, VNO, VNC
V–
ON-state resistance
V+ = 1.65 V, V– = –1.65 V,
25°C
ron
VCOM = 0 V,
ICOM = 20 mA
Full
ON-state resistance
flatness
ron(flat)
V+ = 1.65 V, V– = –1.65 V,
VCOM = –1.8 V, 0 V, 1.5 V,
ICOM = 20 mA
25°C
Full
NO, NC
OFF leakage current(3)
INO(OFF),
INC(OFF)
V+ = 1.95 V, V– = –1.95 V,
VCOM = 1.65 V,
VNO or VNC = –1.65 V
25°C
Full
COM
OFF leakage current(3)
ICOM(OFF)
V+ = 1.95 V, V– = –1.95 V,
VCOM = –1.65 V,
VNO or VNC = 1.65 V
25°C
Full
COM
ON leakage current(3)
ICOM(ON)
V+ = 1.95 V, V– = –1.95 V,
VCOM = 1.95 V,
VNO or VNC = open
25°C
Full
Digital Control Input (IN)
Input logic high
Input logic low
Input leakage current
Dynamic
VIH
VIL
IIH, IIL
VIN = V+, 0 V
Full
V+ – 1.5
Full
V–
Full
Turn-on time(4)
tON
See Figure 2
25°C
Full
Turn-off time(4)
Charge injection(4)
NO, NC
OFF capacitance
COM
OFF capacitance
tOFF
QC
CNO(OFF),
CNC(OFF)
CCOM(OFF)
See Figure 2
CL = 1 nF, See Figure 1
f = 1 MHz, See Figure 4
f = 1 MHz, See Figure 4
25°C
Full
25°C
25°C
25°C
COM
ON capacitance
CCOM(ON)
f = 1 MHz, See Figure 4
25°C
Digital input capacitance
Bandwidth
OFF isolation
Total harmonic distortion
Supply
CI
BW
OISO
THD
VIN = V+, 0 V
RL = 50 Ω, CL = 15 pF,
VNO = 1 VRMS, f = 100 kHz
RL = 50 Ω, CL = 15 pF,
VNO = 1 VRMS, f = 1 MHz
RL = 600 Ω, CL = 50 pF,
VNO = 1 VRMS, f = 20 kHz
25°C
25°C
25°C
25°C
V+ supply current
I+
VIN = 0 V or V+
25°C
Full
V– supply current
I–
VIN = 0 V or V+
25°C
–20
Full
–30
TYP (2)
28
9
90
95
–3.5
6
6
14.5
1.5
464
–83
0.37
MAX
V+
40
47
13
15
5
10
5
10
5
10
V+ – 3.5
0.01
120
150
150
200
20
30
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(2) Typical values are at TA = 25°C.
(3) Leakage parameters are 100% tested at maximum-rated hot operating temperature, and are ensured by correlation at 25°C.
(4) Specified by design, not production tested
UNIT
V
Ω
Ω
nA
nA
nA
V
V
µA
ns
ns
pC
pF
pF
pF
pF
MHz
dB
%
µA
µA
Copyright © 2006–2009, Texas Instruments Incorporated
Submit Documentation Feedback
5
Product Folder Link(s): TS12A4516 TS12A4517