English
Language : 

TPS2102 Datasheet, PDF (5/17 Pages) Texas Instruments – VAUX POWER-DISTRIBUTION SWITCHES
TPS2102, TPS2103
VAUX POWER-DISTRIBUTION SWITCHES
SLVS234A – SEPTEMBER 1999 – REVISED APRIL 2000
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Input voltage range, VI(IN1) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 5 V
Input voltage range, VI(IN2) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 5 V
Input voltage range, VI at EN or EN (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 5 V
Continuous output current, IO(IN1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700 mA
Continuous output current, IO(IN2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 mA
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See dissipation rating table
Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . 260°C
Electrostatic discharge (ESD) protection: Human body model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 kV
Machine model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 V
Charged device model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 V
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
PACKAGE
DBV
D
DISSIPATION RATING TABLE
TA < 25°C
POWER RATING
309 mW
DERATING FACTOR
ABOVE TA = 25°C
3.1 mW/°C
TA = 70°C
POWER RATING
170 mW
568 mW
5.7 mW/°C
313 mW
TA = 85°C
POWER RATING
123 mW
227 mW
recommended operating conditions
MIN MAX UNIT
Input voltage, VI(INx)
2.7
4V
Input voltage, VI at EN and EN
0
4V
Continuous output current, IO(IN1)
Continuous output current, IO(IN2)
500 mA
100‡ mA
Operating virtual junction temperature, TJ
– 40 85 °C
‡ The device can deliver up to 220 mA at IO(IN2). However, operation at the higher current levels will result in greater voltage drop across the device,
and greater voltage droop when switching between IN1 and IN2.
electrical characteristics over recommended operating junction temperature range,
VI(IN1) = V(IN2) = 3.3 V, IO = rated current (unless otherwise noted)
power switch
PARAMETER
TEST
CONDITIONS†
MIN TYP MAX UNIT
rDS(on) On-state resistance
IN1-OUT
IN2-OUT
TJ = 25°C
TJ = 85°C
TJ = 25°C
TJ = 85°C
250
mΩ
300 375
1.3
Ω
1.5 2.1
† Pulse-testing techniques maintain junction temperature close to ambient termperature; thermal effects must be taken into account separately.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5