ELECTRICAL CHARACTERISTICS (continued)
At TA = –40°C to +85°C, VCC = 6 V to 17 V or VCC = VREG = 3 V to 5.5 V, VLED = 5 V, and CVREG = 1 µF, unless otherwise
noted. Typical values are at TA = +25°C and VCC = 12 V.
TLC5971
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ΔIOLC1
Constant current error(2)
(device-to-device in same color group),
OUTXn
All OUTXn on, BCX = 7Fh, VOUTXn = VOUTfix = 1V,
RIREF = 0.82 kΩ (IOLCMax = 60 mA), at same grouped color output
of OUTR0-3, OUTG0-3, and OUTB0-3
±1
±4
%
ΔIOLC2
ΔIOLC3
TTSD
THYS
VIREF
VREG
ΔVREG
ΔVREG1
VSTR
VHYS
Line regulation of constant-current output,
OUTXn (3)
Load regulation of constant-current output,
OUTXn (4)
Thermal shutdown temperature
Thermal shutdown hysteresis
Reference voltage output, IREF
Linear regulator output voltage, VREG
Line regulation of linear regulator, VREG
Load regulation of linear regulator, VREG
Undervoltage lockout release, VREG
Undervoltage lockout hysteresis, VREG
All OUTn on, BCX = 7Fh, VOUTXn = VOUTfix = 1 V,
RIREF = 0.82 kΩ (IOLCMax = 60 mA)
All OUTn on, BCX = 7Fh, VOUTXn = VOUTfix = 1 V,
RIREF = 0.82 kΩ (IOLCMax = 60 mA)
Junction temperature(5)
Junction temperature(5)
RIREF = 0.82 kΩ
VCC = 6 V to 17 V, IREG = 0 mA to –25 mA
VCC = 6 V to 17 V, IREG = 0 mA
VCC = 12 V, IREG = 0 mA to –25 mA
±0.5
±1
%/V
±1
±3
%/V
150
165
180
°C
5
10
20
°C
1.18
1.21
1.24
V
3.1
3.3
3.5
V
90
mV
120
mV
2.5
2.7
2.9
V
300
400
500
mV
(2) The deviation of each color group constant-current average from the ideal constant-current value.
Deviation is calculated by the following formula:
D (%) =
(IOLCX0 + IOLCX1 + IOLCX2 + IOLCX3) - (Ideal Output Current)
4
Ideal Output Current
´ 100
Where: X = R/G/B.
Ideal current is calculated by the following formula for the OUTRn and OUTGn groups:
1.21
IOLCXn(IDEAL) (mA) = 41 ´ RIREF (W)
Where: X = R/G/B.
(3) Line regulation is calculated by this equation:
(IOLCXn at VCC = 5.5 V) - (IOLCXn at VCC = 3 V)
D (%/V) =
(IOLCXn at VCC = 3 V)
100
´
5.5 V - 3 V
Where: X = R/G/B, n = 0-3.
(4) Load regulation is calculated by the equation:
D (%/V) =
(IOLCXn at VOUTXn = 3 V) - (IOLCXn at VOUTXn = 1 V)
(IOLCXn at VOUTXn = 1 V)
100
´
3V-1V
Where: X = R/G/B, n = 0-3.
(5) Not tested, specified by design.