English
Language : 

SN74LS2323 Datasheet, PDF (5/9 Pages) Texas Instruments – DUAL LINE RECEIVER
SN74LS2323
DUAL LINE RECEIVER
SDLS965 − OCTOBER 2004
switching characteristics, VCC = 5 V ±10%, VREF = 2.5 V, TA = 0°C to 70°C
PARAMETER
TEST CONDITIONS
MIN
tPLH(L) Propagation delay time, low- to high-level output from LINE
CL = 50 pF, RL = 500 Ω,
See Figure 1
10
tPHL(L) Propagation delay time, high- to low-level output from LINE
CL = 50 pF, RL = 500 Ω,
See Figure 1
10
tPLH(S)
Propagation delay time,
low- to high-level output from COMSTRB
CL = 50 pF, RL = 500 Ω,
See Figure 1
tPHL(S)
Propagation delay time,
high- to low-level output from COMSTRB
CL = 50 pF, RL = 500 Ω,
See Figure 1
† All typical values are at VCC = 5 V, TA = 25°C.
TYP†
25
25
11
8
MAX
35
35
22
15
UNIT
ns
ns
ns
ns
D.U.T.
CL = 50 pF
PARAMETER MEASUREMENT INFORMATION
T.P.
VCC
2.5 V
500 W
LINE
TEST CIRCUIT
COMSTRB
tPHL(L)
VOH
OUTPUT
VOL
0.8 V
1.5 V
ÎÎÎ tPHL(S)
tPLH(L)
2V
0.8 V
VOLTAGE WAVEFORMS
3V
2V
3V
1.5 V
0V
tPLH(S)
2V
NOTES: A. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, tr and tf ≤ 2 ns, and
duty cycle = 50%.
B. CL includes probe and jig capacitance.
C. All diodes are 1N914 (or equivalent).
D. The outputs are measured one at a time, with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265