English
Language : 

SN74AVCB164245_07 Datasheet, PDF (5/18 Pages) Texas Instruments – 16-BIT DUAL-SUPPLY BUS TRANSCEIVER WITH CONFIGURABLE VOLTAGE TRANSLATION AND 3-STATE OUTPUTS
www.ti.com
SN74AVCB164245
16-BIT DUAL-SUPPLY BUS TRANSCEIVER
WITH CONFIGURABLE VOLTAGE TRANSLATION AND 3-STATE OUTPUTS
SCES394D – JUNE 2002 – REVISED JUNE 2005
Recommended Operating Conditions(1)(2)(3)
over operating free-air temperature range (unless otherwise noted)
VCCA
VCCB
Supply voltage
Supply voltage
VIH High-level input voltage
VIL
Low-level input voltage
VIH High-level input voltage
VIL
Low-level input voltage
VI
Input voltage
VO
Output voltage
Data inputs
Data inputs
Control inputs
(referenced to VCCB)
Control inputs
(referenced to VCCB)
Active state
3-state
VCCI
1.4 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
1.4 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
1.4 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
1.4 V to 1.95 V
1.95 V to 2.7 V
2.7 V to 3.6 V
IOH High-level output current
IOL
Low-level output current
∆t/∆v Input transition rise or fall rate
TA
Operating free-air temperature
VCCO
1.4 V to 1.6 V
1.65 V to 1.95 V
2.3 V to 2.7 V
3 V to 3.6 V
1.4 V to 1.6 V
1.65 V to 1.95 V
2.3 V to 2.7 V
3 V to 3.6 V
MIN
1.4
1.4
VCCI × 0.65
1.7
2
VCCB × 0.65
1.7
2
0
0
0
–40
MAX
3.6
3.6
VCCI × 0.35
0.7
0.8
VCCB × 0.35
0.7
0.8
3.6
VCCO
3.6
–2
–4
–8
–12
2
4
8
12
5
85
UNIT
V
V
V
V
V
V
V
V
mA
mA
ns/V
°C
(1) VCCI is the VCC associated with the data input port.
(2) VCCO is the VCC associated with the data output port.
(3) All unused data inputs of the device must be held at VCCI or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
5