English
Language : 

SN74ALVCH16835 Datasheet, PDF (5/10 Pages) Texas Instruments – 18-BIT UNIVERSAL BUS DRIVER WITH 3-STATE OUTPUTS
SN74ALVCH16835
18-BIT UNIVERSAL BUS DRIVER
WITH 3-STATE OUTPUTS
SCES053E – SEPTEMBER 1995 – REVISED FEBRUARY 1999
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VOH
IOH = –100 µA
IOH = –4 mA
IOH = –6 mA
TEST CONDITIONS
IOH = –12 mA
VCC
1.65 V to 3.6 V
1.65 V
MIN TYP†
VCC–0.2
1.2
2.3 V
2
2.3 V
1.7
2.7 V
2.2
3V
2.4
MAX
UNIT
V
VOL
IOH = –24 mA
IOL = 100 µA
IOL = 4 mA
IOL = 6 mA
IOL = 12 mA
3V
2
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
0.2
0.45
0.4
V
0.7
0.4
IOL = 24 mA
3V
0.55
II
VI = VCC or GND
3.6 V
±5 µA
VI = 0.58 V
1.65 V
25
VI = 1.07 V
1.65 V
–25
VI = 0.7 V
2.3 V
45
II(hold)
VI = 1.7 V
2.3 V
–45
µA
VI = 0.8 V
3V
75
VI = 2 V
VI = 0 to 3.6 V‡
3V
–75
3.6 V
±500
IOZ
VO = VCC or GND
3.6 V
±10 µA
ICC
VI = VCC or GND,
IO = 0
3.6 V
40 µA
∆ICC
One input at VCC – 0.6 V, Other inputs at VCC or GND 3 V to 3.6 V
750 µA
Control inputs
Ci
Data inputs
VI = VCC or GND
3.3 V
3.5
pF
6
Co
Outputs
VO = VCC or GND
3.3 V
7
pF
† All typical values are at VCC = 3.3 V, TA = 25°C.
‡ This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to another.
timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figures 1 through 3)
fclock
tw
Clock frequency
Pulse
LE high
duration CLK high or low
Data before CLK↑
tsu
Setup
time
Data before LE↓
CLK high
CLK low
th
Hold
time
Data after CLK↑
Data after LE↓
CLK high or low
§ This information was not available at the time of publication.
VCC = 1.8 V
MIN MAX
§
§
§
§
§
§
§
§
VCC = 2.5 V
± 0.2 V
MIN MAX
150
3.3
3.3
2.2
1.9
1.3
0.6
1.4
VCC = 2.7 V
MIN MAX
150
3.3
3.3
2.1
1.6
1.1
0.6
1.7
VCC = 3.3 V
± 0.3 V
MIN MAX
150
3.3
3.3
1.7
1.5
1
0.7
1.4
UNIT
MHz
ns
ns
ns
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5