SN74ALVCH16835 Datasheet, PDF (5/10 Pages) Texas Instruments – 18-BIT UNIVERSAL BUS DRIVER WITH 3-STATE OUTPUTS | |||
|
◁ |
SN74ALVCH16835
18-BIT UNIVERSAL BUS DRIVER
WITH 3-STATE OUTPUTS
SCES053E â SEPTEMBER 1995 â REVISED FEBRUARY 1999
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VOH
IOH = â100 µA
IOH = â4 mA
IOH = â6 mA
TEST CONDITIONS
IOH = â12 mA
VCC
1.65 V to 3.6 V
1.65 V
MIN TYPâ
VCCâ0.2
1.2
2.3 V
2
2.3 V
1.7
2.7 V
2.2
3V
2.4
MAX
UNIT
V
VOL
IOH = â24 mA
IOL = 100 µA
IOL = 4 mA
IOL = 6 mA
IOL = 12 mA
3V
2
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
0.2
0.45
0.4
V
0.7
0.4
IOL = 24 mA
3V
0.55
II
VI = VCC or GND
3.6 V
±5 µA
VI = 0.58 V
1.65 V
25
VI = 1.07 V
1.65 V
â25
VI = 0.7 V
2.3 V
45
II(hold)
VI = 1.7 V
2.3 V
â45
µA
VI = 0.8 V
3V
75
VI = 2 V
VI = 0 to 3.6 Vâ¡
3V
â75
3.6 V
±500
IOZ
VO = VCC or GND
3.6 V
±10 µA
ICC
VI = VCC or GND,
IO = 0
3.6 V
40 µA
âICC
One input at VCC â 0.6 V, Other inputs at VCC or GND 3 V to 3.6 V
750 µA
Control inputs
Ci
Data inputs
VI = VCC or GND
3.3 V
3.5
pF
6
Co
Outputs
VO = VCC or GND
3.3 V
7
pF
â All typical values are at VCC = 3.3 V, TA = 25°C.
â¡ This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to another.
timing requirements over recommended operating free-air temperature range (unless otherwise
noted) (see Figures 1 through 3)
fclock
tw
Clock frequency
Pulse
LE high
duration CLK high or low
Data before CLKâ
tsu
Setup
time
Data before LEâ
CLK high
CLK low
th
Hold
time
Data after CLKâ
Data after LEâ
CLK high or low
§ This information was not available at the time of publication.
VCC = 1.8 V
MIN MAX
§
§
§
§
§
§
§
§
VCC = 2.5 V
± 0.2 V
MIN MAX
150
3.3
3.3
2.2
1.9
1.3
0.6
1.4
VCC = 2.7 V
MIN MAX
150
3.3
3.3
2.1
1.6
1.1
0.6
1.7
VCC = 3.3 V
± 0.3 V
MIN MAX
150
3.3
3.3
1.7
1.5
1
0.7
1.4
UNIT
MHz
ns
ns
ns
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5
|
▷ |