English
Language : 

MC33063A-Q1_15 Datasheet, PDF (5/26 Pages) Texas Instruments – MC33063A-Q1 1.5-A Peak Boost, Buck, Inverting Switching Regulator
www.ti.com
MC33063A-Q1
SLLS654C – APRIL 2005 – REVISED DECEMBER 2014
6.5 Oscillator Characteristics
VCC = 5 V, TA = full operating range (unless otherwise noted) (see block diagram)
PARAMETER
TEST CONDITIONS
fosc
Ichg
Idischg
Idischg/Ichg
VIpk
Oscillator frequency
Charge current
Discharge current
Discharge-to-charge current ratio
Current-limit sense voltage
VPIN5 = 0 V, CT = 1 nF
VCC = 5 V to 40 V
VCC = 5 V to 40 V
VPIN7 = VCC
Idischg = Ichg
TA
25°C
25°C
25°C
25°C
25°C
MIN TYP MAX UNIT
24
33
42 kHz
24
35
42 μA
140 220 260 μA
5.2 6.5 7.5
250 300 350 mV
6.6 Output Switch Characteristics(1)
VCC = 5 V, TA = full operating range (unless otherwise noted). See the Functional Block Diagram.
PARAMETER
TEST CONDITIONS
TA
MIN
VCE(sat)
Saturation voltage –
Darlington connection
ISW = 1 A, pins 1 and 8 connected
Full range
TYP MAX UNIT
1 1.3 V
VCE(sat)
Saturation voltage –
non-Darlington connection(2)
ISW = 1 A, RPIN8 = 82 Ω to VCC,
Forced β ~ 20
Full range
0.45 0.7 V
hFE
IC(off)
DC current gain
Collector off-state current
ISW = 1 A, VCE = 5 V
VCE = 40 V
25°C
Full range
50
75
0.01
100 μA
(1) Low duty-cycle pulse testing is used to maintain junction temperature as close to ambient temperature as possible.
(2) In the non-Darlington configuration, if the output switch is driven into hard saturation at low switch currents (≤300 mA) and high driver
currents (≥30 mA), it may take up to 2 μs for the switch to come out of saturation. This condition effectively shortens the off time at
frequencies ≥30 kHz, becoming magnified as temperature increases. The following output drive condition is recommended in the non-
Darlington configuration:
Forced β of output switch = IC,SW / (IC,driver – 7 mA) ≥ 10, where ∼7 mA is required by the 100-Ω resistor in the emitter of the driver to
forward bias the Vbe of the switch.
6.7 Comparator Characteristics
VCC = 5 V, TA = full operating range (unless otherwise noted). See the Functional Block Diagram.
PARAMETER
TEST CONDITIONS
TA
MIN
Vth
Threshold voltage
25°C
1.225
Full range 1.21
ΔVth Threshold-voltage line regulation
IIB
Input bias current
VCC = 5 V to 40 V
VIN = 0 V
Full range
Full range
TYP MAX UNIT
1.25 1.275
V
1.29
1.4
5 mV
–20 –400 nA
6.8 Total Device Characteristics
VCC = 5 V, TA = full operating range (unless otherwise noted). See the Functional Block Diagram.
PARAMETER
TEST CONDITIONS
TA
ICC
Supply current
VCC = 5 V to 40 V, CT = 1 nF,
VPIN7 = VCC, VPIN5 > Vth,
VPIN2 = GND, All other pins open
Full range
MIN MAX UNIT
4 mA
Copyright © 2005–2014, Texas Instruments Incorporated
Product Folder Links: MC33063A-Q1
Submit Documentation Feedback
5