LM25007
www.ti.com
SNVS401C – JANUARY 2006 – REVISED FEBRUARY 2013
Electrical Characteristics(1)
Specifications with standard type are for TJ = 25°C only; limits in boldface type apply over the full Operating Junction
Temperature (TJ) range. Minimum and Maximum limits are guaranteed through test, design, or statistical correlation. Typical
values represent the most likely parametric norm at TJ = 25°C, and are provided for reference purposes only. Unless
otherwise stated the following conditions apply: VIN = 24V, RON = 200kΩ. .
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
Startup Regulator
VCC Reg VCC Regulator Output
VCC Current Limit
VCC Supply
VCC undervoltage Lockout Voltage
(VCC increasing)
VCC Undervoltage Hysteresis
VCC UVLO Delay (filter)
Operating Current (ICC)
Shutdown/Standby Current
(2)
Non-Switching, FB = 3V
RON/SD = 0V
6.6
7
7.4
V
11
mA
6.3
V
206
mV
3
µs
500
675
µA
70
150
µA
Switch Characteristics
Buck Switch Rds(on)
ITEST = 200mA,
VBST −VSW = 6.3V(3)
0.74
1.34
Ω
Gate Drive UVLO (VBST – VSW) Rising
3.4
4.5
5.5
V
Gate Drive UVLO Hysteresis
400
mV
Current Limit
Current Limit Threshold
535
725
900
mA
Current Limit Response Time
Iswitch Overdrive = 0.1A Time to
Switch Off
225
ns
OFF time generator (test 1)
FB=0V, RCL = 100K
17
µs
OFF time generator (test 2)
FB=2.3V, RCL = 100K
2.65
µs
On Time Generator
TON -1
Vin = 10V
Ron = 200K
2.15
2.77
3.5
µs
TON -2
Vin = 40V
Ron = 200K
450
615
810
ns
Remote Shutdown Threshold
Rising
0.45
0.7
1.1
V
Remote Shutdown Hysteresis
40
mV
Minimum Off Time
Minimum Off Timer
FB = 0V
300
ns
Regulation and OV Comparators
FB Reference Threshold
Internal reference
Trip point for switch ON
2.445
2.5
2.550
V
FB Over-Voltage Threshold
Trip point for switch OFF
2.875
V
FB Bias Current
100
nA
Thermal Shutdown
Tsd
Thermal Shutdown Temp.
165
°C
Thermal Shutdown Hysteresis
25
°C
Thermal Resistance
θJA
Junction to Ambient
DGK Package
NGT Package
200
°C/W
40
°C/W
(1) All limits are guaranteed. All electrical characteristics having room temperature limits are tested during production with TA = TJ = 25°C.
All hot and cold limits are guaranteed by correlating the electrical characteristics to process and temperature variations and applying
statistical process control.
(2) The VCC output is intended as a self bias for the internal gate drive power and control circuits. Device thermal limitations limit external
loading.
(3) For devices procured in the WSON-8 package the Rds(on) limits are guaranteed by design characterization data only.
Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LM25007
Submit Documentation Feedback
5