English
Language : 

CD74HC366 Datasheet, PDF (5/13 Pages) Texas Instruments – High Speed CMOS Logic Hex Buffer/Line Driver, Three-State Non-Inverting and Inverting
CD54/74HC365, CD54/74HCT365, CD54/74HC366
DC Electrical Specifications (Continued)
TEST
CONDITIONS
25oC
-40oC TO 85oC
PARAMETER
SYMBOL VI (V) IO (mA) VCC (V) MIN TYP MAX MIN
Three-State Leakage
IOZ
VIL or VO =
6
Current
VIH VCC or
GND
-
- ±0.5
-
MAX
±5.0
HCT TYPES
High Level Input
Voltage
VIH
-
-
4.5 to 2
-
-
2
-
5.5
Low Level Input
Voltage
VIL
-
-
4.5 to -
- 0.8
-
0.8
5.5
High Level Output
Voltage
CMOS Loads
VOH
VIH or -0.02
4.5
4.4
-
-
4.4
-
VIL
High Level Output
Voltage
TTL Loads
-4
4.5 3.98 -
-
3.84
-
Low Level Output
Voltage
CMOS Loads
VOL
VIH or 0.02
4.5
-
- 0.1
-
0.1
VIL
Low Level Output
Voltage
TTL Loads
4
4.5
-
- 0.26
-
0.33
Input Leakage
Current
II
VCC to
0
5.5
-
- ±0.1
-
±1
GND
Quiescent Device
Current
ICC
VCC or
0
5.5
-
-
8
-
80
GND
Additional Quiescent
∆ICC
VCC
-
4.5 to - 100 360
-
450
Device Current Per
-2.1
5.5
Input Pin: 1 Unit Load
(Note 2)
Three-State Leakage
IOZ
VIL or VO =
5.5
-
- ±0.5
-
±5.0
Current
VIH VCC or
GND
NOTE:
2. For dual-supply systems theoretical worst case (VI = 2.4V, VCC = 5.5V) specification is 1.8mA.
HCT Input Loading Table
-55oC TO 125oC
MIN MAX UNITS
-
±10
µA
2
-
V
-
0.8
V
4.4
-
V
3.7
-
V
-
0.1
V
-
0.4
V
-
±1
µA
-
160
µA
-
490
µA
-
±10
µA
INPUT
UNIT LOADS
OE1
0.6
All Others
0.55
NOTE: Unit Load is ∆ICC limit specified in DC Electrical
Specifications table, e.g., 360µA max at 25oC.
Switching Specifications - HC/HCT365 Input tr, tf = 6ns
PARAMETER
HC TYPES
Propagation Delay,
Data to Outputs
HC/HCT365
TEST
SYMBOL CONDITIONS VCC (V)
tPLH, tPHL CL = 50pF
2
4.5
6
CL = 15pF
5
25oC
TYP MAX
-40oC TO 85oC
MAX
-
105
130
-
21
26
-
18
22
8
-
-
-55oC TO
125oC
MAX
160
32
27
-
UNITS
ns
ns
ns
ns
5