English
Language : 

CD74AC153 Datasheet, PDF (5/7 Pages) Texas Instruments – Dual 4-Input Multiplexer
CD74AC153, CD74ACT153
Switching Specifications Input tr, tf = 3ns, CL = 50pF (Worst Case)
-40oC TO 85oC
-55oC TO 125oC
PARAMETER
AC TYPES
SYMBOL
VCC (V)
MIN
TYP
MAX
MIN
TYP
MAX UNITS
Propagation Delay, S0, S1, to Y tPLH, tPHL
1.5
-
3.3
7.2
(Note 9)
-
227
-
-
25.5
7
-
250
ns
-
28
ns
5
5.2
(Note 10)
-
18.2
5
-
20
ns
Propagation Delay, nI to Y
tPLH, tPHL
1.5
-
-
151
-
-
166
ns
3.3
4.8
-
16.9
4.7
-
18.6
ns
5
3.4
-
12.1
3.3
-
13.3
ns
Propagation Delay, nE to Y
tPLH, tPHL
1.5
-
-
134
-
-
148
ns
3.3
4.3
-
15
4.1
-
16.5
ns
5
3.1
-
10.7
3
-
11.8
ns
Input Capacitance
CI
-
Power Dissipation Capacitance
CPD
-
(Note 11)
-
-
10
-
-
10
pF
-
93
-
-
93
-
pF
ACT TYPES
Propagation Delay, S0, S1, to Y tPLH, tPHL
5
5.7
(Note 10)
-
20
5.5
-
22
ns
Propagation Delay, nI to Y
tPLH, tPHL
5
Propagation Delay, nE to Y
tPLH, tPHL
5
Input Capacitance
CI
-
Power Dissipation Capacitance
CPD
-
(Note 11)
4.6
-
16.4
4.5
-
18
ns
3.2
-
11.5
3.2
-
12.6
ns
-
-
10
-
-
10
pF
-
93
-
-
93
-
pF
NOTES:
8. Limits tested at 100%.
9. 3.3V Min at 3.6V, Max at 3V.
10. 5V Min at 5.5V, Max at 4.5V.
11. CPD is used to determine the dynamic power consumption per multiplexer.
AACC:TP: PDD==VVCCCC2 2fi
(CPD + CL)
fi (CPD + CL)
+
VCC
∆ICC
where
fi
=
input
frequency,
CL
=
output
load
capacitance,
VCC
=
supply
voltage.
5