Switching Specifications Input tr, tf = 6ns (Continued)
PARAMETER
TEST
VCC
SYMBOL CONDITIONS (V)
25oC
-40oC TO 85oC -55oC TO 125oC
MIN TYP MAX MIN MAX MIN MAX UNITS
Enable to Output
tPLH, tPHL CL = 50pF
2
-
- 135
-
170
-
205
ns
4.5
-
- 27
-
34
-
41
ns
HC157
HCT157
CL =15pF
5
- 11 -
-
-
-
-
ns
- 12 -
-
-
-
-
ns
Select to Output
CL = 50pF
tPLH, tPHL CL = 50pF
6
-
- 23
-
29
-
35
ns
2
-
- 145
-
180
-
220
ns
4.5
-
- 29
-
36
-
44
ns
HC157
HCT157
CL =15pF
5
- 12 -
-
-
-
-
ns
- 15 -
-
-
-
-
ns
Power Dissipation
Capacitance (Notes 3, 4)
CPD
CL = 50pF
-
6
-
- 25
-
31
-
38
ns
5
HC157
- 62 -
-
-
-
-
pF
HCT157
- 70 -
-
-
-
-
pF
HC/HCT158 TYPES
Data to Output
tPLH, tPHL CL = 50pF
2
-
- 140
-
175
-
210
ns
4.5
-
- 28
-
35
-
42
HC158
HCT 158
CL =15pF
5
- 11 -
-
-
-
-
ns
- 13 -
-
-
-
-
ns
Enable to Output
CL = 50pF
tPLH, tPHL CL = 50pF
6
-
- 24
-
30
-
36
ns
2
-
- 160
-
200
-
240
ns
4.5
-
- 32
-
40
-
48
ns
HC158
HCT 158
CL =15pF
5
- 13 -
-
-
-
-
ns
- 15 -
-
-
-
-
ns
Select to Output
CL = 50pF
tPLH, tPHL CL = 50pF
6
-
- 27
-
34
-
41
ns
2
-
- 150
-
190
-
225
ns
4.5
-
- 30
-
38
-
45
ns
HC158
HCT 158
CL =15pF
5
- 12 -
-
-
-
-
ns
- 14 -
-
-
-
-
ns
CL = 50pF
6
-
- 26
-
33
-
38
ns
Output Transition Time
tTLH, tTHL CL = 50pF
2
-
- 75
-
95
-
110
ns
4.5
-
- 15
-
19
-
22
ns
6
-
- 13
-
16
-
19
ns
Power Dissipation
CPD
-
5
Capacitance (Notes 3, 4)
HC158
- 35 -
-
-
-
-
pF
HCT 158
- 35 -
-
-
-
-
pF
Input Capacitance
CIN
CL = 50pF
-
-
- 10
-
10
-
NOTES:
3. CPD is used to determine the dynamic power consumption, per multiplexer.
4. PD = VCC2 fi (CPD + CL) where fi = input frequency, CL = output load capacitance, VCC = supply voltage.
10
pF