74LS04 Datasheet, PDF (5/10 Pages) Motorola, Inc – HEX INVERTER | |||
|
◁ |
SN5404, SN54LS04, SN54S04,
SN7404, SN74LS04, SN74S04
HEX INVERTERS
SDLS029B â DECEMBER 1983 â REVISED FEBRUARY 2002
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)â
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI: â04, âS04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
âLS04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Package thermal impedance, θJA (see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 65°C to 150°C
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. This are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect to network ground terminal.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
VCC
VIH
VIL
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
Operating free-air temperature
SN5404
MIN NOM
4.5
5
2
â 55
MAX
5.5
0.8
â0.4
16
125
SN7404
MIN NOM
4.75
5
2
0
MAX
5.25
0.8
â0.4
16
70
UNIT
V
V
V
mA
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONSâ¡
SN5404
MIN TYP§ MAX
SN7404
MIN TYP§
VIK
VCC = MIN,
II = â 12 mA
â 1.5
VOH
VCC = MIN,
VIL = 0.8 V, IOH = â0.4 mA
2.4 3.4
2.4 3.4
VOL
VCC = MIN,
VIH = 2 V,
IOL = 16 mA
0.2 0.4
0.2
II
VCC = MAX,
VI = 5.5 V
1
IIH
VCC = MAX,
VI = 2.4 V
40
IIL
VCC = MAX,
VI = 0.4 V
â 1.6
IOS¶
VCC = MAX
â20
â55 â18
ICCH
VCC = MAX,
VI = 0 V
6
12
6
ICCL
VCC = MAX,
VI = 4.5 V
18
33
18
â¡ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
§ All typical values are at VCC = 5 V, TA = 25°C.
¶ Not more than one output should be shorted at a time.
MAX
â 1.5
0.4
1
40
â 1.6
â55
12
33
UNIT
V
V
V
mA
µA
mA
mA
mA
mA
switching characteristics, VCC = 5 V, TA = 25°C (see Figure 1)
PARAMETER
tPLH
tPHL
FROM
(INPUT)
A
TO
(OUTPUT)
Y
TEST CONDITIONS
RL = 400 â¦,
CL = 15 pF
SN5404
SN7404
MIN TYP
12
8
MAX
22
15
UNIT
ns
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265