Electrical Characteristics for 1.8-V Supply(1)(2)
V+ = 1.65 V to 1.95 V, TA = –40°C to 85°C, VIH = 1 V, VIL = 0.4 V (unless otherwise noted)
PARAMETER
Analog Switch
SYMBOL
TEST CONDITIONS
TA
MIN
Analog signal range
ON-state resistance
VCOM, VNO
ron
V+ = 1.8 V, ICOM = –10 mA,
VNO = 0.9 V
0
25°C
Full
ON-state resistance match
between channels(4)
∆ron
V+ = 1.8 V, ICOM = –10 mA,
VNO = 0.9 V
25°C
Full
ON-state resistance
flatness (5)
ron(flat)
V+ = 1.8 V, ICOM = –10 mA,
0 ≤ VNO ≤ V+
25°C
Full
NO
OFF leakage current(6)
INO(OFF)
V+ = 1.95 V, VCOM = 0.15 V, 1.65 V,
VNO = 1.8 V, 0.15 V
25°C
–1
Full
–10
COM
OFF leakage current(6)
ICOM(OFF)
V+ = 1.95 V, VCOM = 0.15 V, 1.65 V,
VNO = 1.65 V, 0.15 V
25°C
–1
Full
–10
COM
ON leakage current(6)
ICOM(ON)
V+ = 1.95 V, VCOM = 0.15 V, 1.65 V,
VNO = 0.15 V, 1.65 V, or floating
25°C
–1
Full
–3
Dynamic
Turn-on time
tON
VNO = 1.5 V, RL = 50 Ω,
CL = 35 pF, See Figure 14
25°C
Full
Turn-off time
tOFF
VNO = 1.5 V, RL = 50 Ω,
CL = 35 pF, See Figure 14
25°C
Full
Charge injection
QC
VGEN = 0, RGEN = 0, CL = 1 nF,
See Figure 15
25°C
NO OFF capacitance
COM OFF capacitance
COM ON capacitance
Bandwidth
OFF isolation(7)
CNO(OFF)
CCOM(OFF)
CCOM(ON)
BW
OISO
f = 1 MHz, See Figure 16
f = 1 MHz, See Figure 16
f = 1 MHz, See Figure 16
RL = 50 Ω, Switch ON
RL = 50 Ω, CL = 5 pF,
See Figure 17
f = 10 MHz
f = 100 MHz
25°C
25°C
25°C
25°C
25°C
Crosstalk
XTALK
RL = 50 Ω, CL = 5 pF,
See Figure 17
f = 10 MHz
f = 100 MHz
25°C
Total harmonic distortion
THD
Digital Control Inputs (IN1–IN4)
f = 20 Hz to 20 kHz, VCOM RL = 32 Ω
= 2 VP-P
RL = 600 Ω
25°C
Input logic high
Input logic low
Input leakage current
VIH
VIL
IIN
VI = 0 or V+
Full
1
Full
25°C
Full
–10
Supply
Power-supply range
Positive-supply current
V+
I+
VI = 0 or V+
1.6
25°C
Full
TYP (3)
1
0.09
0.7
0.5
0.5
0.01
6
5
3.2
23
20
43
123
–61
–36
–95
–73
0.14
0.013
0.1
www.ti.com
MAX UNIT
V+ V
1.5
Ω
2
0.15
Ω
0.25
0.9
Ω
1.5
1
nA
10
1
nA
10
1
nA
3
18
ns
20
10
ns
12
pC
pF
pF
pF
MHz
dB
dB
%
V
0.4 V
5
nA
10
3.6 V
0.05
µA
0.5
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.
(2) Parts are tested at 85°C and specified by design and correlation over the full temperature range.
(3) Typical values are at TA = 25°C.
(4) ∆ron = ron(max) – ron(min)
(5) Flatness is defined as the difference between the maximum and minimum value of ron as measured over the specified analog signal
ranges.
(6) Leakage parameters are 100% tested at the maximum-rated hot operating temperature and specified by correlation at TA = 25°C.
(7) OFF isolation = 20log10 (VCOM/VNO), VCOM = output, VNO = input to OFF switch