Electrical Characteristics
VCC+ = 5 V, VCC– = GND, VO = 1.4 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VIO
Input offset voltage
RS = 0, 5 V < VCC+ < 30 V,
0 < VIC < (VCC+ – 1.5 V)
IIO
Input offset current
IIB
AVD
VICR
Input bias current(1)
Large-signal differential voltage VCC = 15 V, RL = 2 kΩ,
amplification
VO = 1.4 V to 11.4 V
Common-mode input voltage(2) VCC = 30 V
VOH
High-level output voltage
VCC = 30 V
RL = 2 kΩ
RL = 10 kΩ
VCC = 5 V
RL = 2 kΩ
VOL
Low-level output voltage
GBP Gain bandwidth product
SR
Slew rate
φm
Phase margin
CMRR Common-mode rejection ratio
ISOURCE Output source current
ISINK
Output sink current
IO
SVR
Short-circuit to GND
Supply-voltage rejection ratio
ICC
Total supply current
THD
eN
Total harmonic distortion
Equivalent input noise voltage
RL = 10 kΩ
VCC = 30 V, VI = 10 mV, RL = 2 kΩ,
f = 100 kHz, CL = 100 pF
VCC = 15 V, VI = 0.5 V to 3 V,
RL = 2 kΩ, CL = 100 pF, unity gain
RS ≤ 10 kΩ
VCC = 15 V, VO = 2 V, VID = 1 V
VCC = 15 V, VID = 1 V
VO = 2 V
VO = 0.2 V
VCC = 15 V
VCC = 5 V to 30 V
VCC = 5 V
No load
VCC = 30 V
VCC = 5 V
VCC = 30 V
VCC = 30 V, VO = 2 Vpp, AV = 20 dB,
RL = 2 kΩ, f = 1 kHz, CL = 100 pF
VCC = 30 V, f = 1 kHz, RS = 100 Ω
TA
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
25°C
www.ti.com
MIN
50
25
0
0
26
25.5
27
26.5
3.5
3
TYP
0.5
2
20
100
MAX
4
5
30
50
150
200
UNIT
mV
nA
nA
V/mV
VCC+ – 1.5
V
VCC+ – 2
27
28
V
5
15
V
20
0.8
MHz
0.4
60
65
85
20
40
10
20
12
50
40
65
110
500
600
600
0.015
50
V/µs
°
dB
mA
mA
µA
60 mA
dB
800
900
µA
900
1000
%
nV/√Hz
(1) The direction of the input current is out of the device. This current essentially is constant, independent of the state of the output, so no
loading change exists on the input lines.
(2) The input common-mode voltage of either input signal should not be allowed to go negative by more than 0.3 V. The upper end of the
common-mode voltage range is VCC+ – 1.5 V, but either or both inputs can go to 32 V without damage.
4