English
Language : 

TP3064A Datasheet, PDF (4/20 Pages) Texas Instruments – MONOLITHIC SERIAL INTERFACE COMBINED PCM CODEC AND FILTER
TP3064A, TP3067A, TP13064A, TP13067A
MONOLITHIC SERIAL INTERFACE
COMBINED PCM CODEC AND FILTER
SCTS025C – SEPTEMBER 1992 –REVISED JULY 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Supply voltage, VBB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 7 V
Voltage range at any analog input or output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.3 V to VBB – 0.3 V
Voltage range at any digital input or output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC + 0.3 V to GND – 0.3 V
Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: TP3064A, TP3067A . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TP13064A, TP13067A . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: DW or N package . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
PACKAGE
DW
N
DISSIPATION RATING TABLE
TA ≤ 25°C
POWER RATING
1025 mW
DERATING FACTOR
ABOVE TA = 25°C
8.2 mW/°C
TA = 70°C
TA = 85°C
POWER RATING POWER RATING
656 mW
533 mW
1150 mW
9.2 mW/°C
736 mW
598 mW
recommended operating conditions (see Note 2)
MIN NOM MAX UNIT
Supply voltage, VCC
4.75
5 5.25 V
Supply voltage, VBB
– 4.75 – 5 – 5.25 V
High-level input voltage, VIH
2.2
V
Low-level input voltage, VIL
Common-mode input voltage range, VICR‡
0.6 V
± 2.5 V
Load resistance at GSX, RL
10
kΩ
Load capacitance at GSX, CL
50 pF
Operating free-air temperature, TA
TP3064A, TP3067A
0
TP13064A, TP13067A
– 40
70
°C
85
‡ Measure with CMRR > 60 dB.
NOTE 2: To avoid possible damage to these CMOS devices and resulting reliability problems, the power-up procedure described in the device
power-up sequence paragraphs later in this document should be followed.
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265