English
Language : 

SN74F153DR Datasheet, PDF (4/18 Pages) Texas Instruments – DUAL 1-OF-4 DATA SELECTORS MULTIP LEXERS
SN54F153, SN74F153
DUAL 1ĆOFĆ4 DATA SELECTORS/MULTIPLEXERS
ą
SDFS052A − D2932, MARCH 1987 − REVISED OCTOBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −1.2 V to 7 V
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA to 5 mA
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Current into any output in the low state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA
Operating free-air temperature range: SN54F153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74F153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage rating may be exceeded provided that the input current rating is observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
SN54F153
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
−1
20
− 55
125
SN74F153
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
−1
20
0
70
UNIT
V
V
V
mA
mA
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54F153
MIN TYP‡ MAX
SN74F153
MIN TYP‡ MAX
VIK
VCC = 4.5 V,
II = − 18 mA
− 1.2
VOH
VCC = 4.5 V,
VCC = 4.75 V,
IOH = − 1 mA
IOH = − 1 mA
2.5 3.4
2.5 3.4
2.7
VOL
VCC = 4.5 V,
IOL = 20 mA
0.3 0.5
0.3
II
VCC = 5.5 V,
VI = 7 V
0.1
IIH
VCC = 5.5 V,
VI = 2.7 V
20
IIL
IOS§
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.5 V
VO = 0
− 0.6
− 60
−150 −60
ICC
VCC = 5.5 V,
VI = 0
12
20
12
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
− 1.2
0.5
0.1
20
− 0.6
−150
20
UNIT
V
V
V
mA
µA
mA
mA
mA
2−4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443