and no longer is supplied.
recommended operating conditions
VCC
VIH
VIL
VOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
High-level output voltage
Low-level output current
Operating free-air temperature
SN5405
MIN NOM MAX
4.5
5 5.5
2
0.8
5.5
16
−55
125
SN7405
MIN NOM MAX
4.75
5 5.25
2
0.8
5.5
16
0
70
UNIT
V
V
V
V
mA
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS†
SN5405
MIN TYP‡ MAX
SN7405
MIN TYP‡ MAX
VIK
VCC = MIN,
II = −12 mA
−1.5
−1.5
IOH
VCC = MIN,
VIL = 0.8 V
VOH = 5.5 V VIL = 0.7 V
0.25
0.25
VOL
VCC = MIN,
VIH = 2 V, IOL = 16 mA
0.2 0.4
0.2 0.4
II
VCC = MAX,
VI = 5.5 V
1
1
IIH
VCC = MAX,
VI = 2.4 V
40
40
IIL
VCC = MAX,
VI = 0.4 V
−1.6
−1.6
ICCH
VCC = MAX,
VI = 0 V
6
12
6
12
ICCL
VCC = MAX,
VI = 4.5 V
18
33
18
33
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ All typical values are at VCC = 5 V, TA = 25°C.
UNIT
V
mA
V
mA
µA
mA
mA
mA
switching characteristics, VCC = 5 V, TA = 25°C (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
tPLH
A
tPHL
RL = 4 kΩ
Y
RL = 400 Ω CL = 15 pF
MIN TYP MAX UNIT
40
55
ns
8
15
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265