English
Language : 

SLUS785 Datasheet, PDF (4/5 Pages) Texas Instruments – bq27500 Errata (SLUS785)
bq27500 Firmware Revision and Errata List
6 bq27500 Firmware Revision and Errata List
www.ti.com
Firmware
Revision
Shipment
Form
IC Lot Codes
Discrepencies
v1.06
Samples and
production
shipments
Any other code not
listed for Revision
v1.00 or v1.02.
1. Fuel gauging with Load Mode = 1 (indicating the constant power
model) does not operate properly.
• SLUS785D data sheet: Section 5.2.1 allows the selection
of a constant current fuel gauge model or constant power
fuel gauge model.
• Operation: Only the constant current fuel gauge model
operates (Load Mode = 0) properly. For the bq27500, this
is the recommended configuration.
The affected material can be identified by the lot code on 2. The part may not enter HIBERNATE mode with [HIBERNATE] = 1
the bq27500 IC in the location shown in Figure 1
in CONTROL_STATUS
• SLUS785D data sheet: Section 5.7.4. The gauge enters
HIBERNATE when HIBERNATE = 1 in
CONTROL_STATUS register and a valid OCV
measurement is tak0en AND the current drops below
Hibernate Current.
• Operation: The HIBERNATE bit will clear if the battery is
not in a relaxed state preventing entry into HIBERNATE
mode.
3 The part enters HIBERNATE mode based on battery voltage less
than Hibernate Voltage unconditionally.
•
SLUS785D Datasheet: Section 5.7.4. The gauge enters
HIBERNATE when a valid OCV measurement is taken.
•
Operation: The part enters HIBERNATE mode
unconditionally with Vcell (battery voltage) less than
Hibernate Voltage.
4 The part may exit HIBERNATE mode on I2C communication
which is not directed to the bq27500.
•
SLUS785D data sheet: Section 5.7.4. I2C communication
that is not directed to the gauge does not wake the
gauge.
•
Operation: The part may exit HIBERNATE mode on 12C
communication which is not directed to the gauge
5 The part does not always take an OCV reading upon exiting
HIBERNATE mode.
•
SLUS785D data sheet: Section 5.7.4. After waking, the
gauge can proceed the initialization of battery information
(eg OCV).
•
Operation: The part may not always take an OCV reading
upon exiting HIBERNATE mode.
Firmware revision v1.08 of bq27500 (Part number bq27500-V100) corrects the discrepancies in firmware revision v1.06.
4
bq27500 Errata (SLUS785)
SLUZ015B – October 2007 – Revised September 2008
Submit Documentation Feedback