English
Language : 

PTB48560A Datasheet, PDF (4/28 Pages) Texas Instruments – 30-W, 48-V INPUT DC/DC CONVERTERS WITH AUTO-TRACK TM SEQUENCING
PTB48560A, PTB48560B
PTB48560C
SLTS236A – MARCH 2005 – REVISED OCTOBER 2005
www.ti.com
PTB48560B ELECTRICAL CHARACTERISTICS
(Unless otherwise stated, TA = 25°C, VI = 48 V, VO = 3.3 V, CO = 220 µF, and IO = IOmax)
PARAMETER
TEST CONDITIONS
PTB48560B
MIN
TYP
MAX
IO
Output current
Over VI range
VI
Input voltage range
Over IO range
Set-point voltage tolerance
IO Bus
IO Seq
Sum total, (IO Bus + IO Seq)
0.25 (1)
0
0.25
36
48
±1 (4)
8 (2)
4 (3)
8
75
Temperature variation
-40°C ≤ TA ≤ 85°C
Line regulation
VO
Load regulation
Over VI range
Over IO range
Total output voltage variation Includes set-point, line, load, –40°C ≤ TA ≤ 85°C
Adjust range
Over VI range
RSET = 5.36 kΩ, VO = 3.3 V
η
Efficiency
RSET = 40.2 kΩ, VO = 2.5 V
RSET = open , VO = 1.8 V
VO Ripple (peak-to-peak)
20-MHz bandwidth
Transient response
0.1 A/µs load step,
50% to 100%
IOmax
Recovery time
VO over/undershoot
Input current
Track connected to -Sense
±0.5
±7
±33
±13
±33
±2
±3 (4)
1.8
3.6
82%
79%
74%
50
100
±150
-0.13
Track input (pin 5)
Open-circuit voltage
Input slew rate limits
0
0.1 (5)
VO Bus
1
Referenced to -VI
Output enable inputs (pins 2, 3)
Standby input current
Pins 2 and 3 open
Input high voltage (VIH)
Input low voltage (VIL)
Input low current (IIL)
2
Open (6)
-0.2
0.8
0.48
8
16
IO (tot) Overcurrent threshold
UVLO Undervoltage lockout
ƒS
Switching frequency
Internal input capacitance
Shutdown, followed by autorecovery
Over VI range
VI increasing
VI decreasing
12
34
33
400
500
600
1
External output capacitance
Isolation voltage
Between both outputs and VO COM
Input-output
220
1,500
5,000
Isolation capacitance
Input-output
2,000
Isolation resistance
Input-output
10
MTBF Reliability
Telcordia SR-332 50% stress, TA = 40°C, ground
benign
3.6
UNIT
A
V
%VO
%VO
mV
mV
%VO
V
mVpp
µs
mV
mA
V/ms
V
mA
mA
A
V
kHz
µF
µF
Vdc
pF
MΩ
106 Hr
(1) The converter requires a minimum load current at either the VO Seq or VO Bus output for proper operation. The converter is not
damaged when operated under a no-load condition.
(2) See temperature derating curves for safe operating area (SOA), to determine output current derating at elevated ambient temperatures.
(3) When load current is supplied from the VO Seq output, the module exhibits higher power dissipation and slightly lower operating
efficiency.
(4) The set-point voltage tolerance is affected by the tolerance and stability of RSET. The stated limit is unconditionally met if RSET has a
tolerance of 1%, with 100 ppm/°C temperature stability.
(5) When controlling the Track input from an external source, the slew rate of the applied signal must be greater than the minimum limit.
Failure to allow the voltage to completely rise to the voltage at the VO (bus) output, at no less than the minimum specified rate, may
thermally overstress the converter.
(6) The PEN and NEN inputs each have an internal pullup resistor. If the enable feature is not used, the PEN input (pin 2) should be left
open circuit and the NEN input (pin 3) permanently connected to –VI. A discrete MOSFET or bipolar transistor is recommended for the
enable control. The open-circuit voltage is less than 10 V. See the Application Information for a more detailed description.
4