English
Language : 

PT6980 Datasheet, PDF (4/12 Pages) Texas Instruments – 10-A 12V-Input Dual Output Integrated Switching Regulator
PT6982
10.5-A 12V-Input Dual Output
Integrated Switching Regulator
PT6982 Performance Specifications (Unless otherwise stated, Ta =25°C, Vin =12V, C1 =560µF, C2 =330µF, Io1 =Io1typ, and Io2 =Io2typ)
PT6982 (3.3V/2.5V)
Characteristic
Symbol
Conditions
Min
Typ
Max
Units
Output Current
Input Voltage Range
Set Point Voltage Tolerance
Temperature Variation
Line Regulation
Load Regulation
Total Output Voltage Variation
Efficiency
Io1
Io2
Io1
Io2
Vin
Vo tol
Regtemp
Regline
Regload
∆Votot
η
Ta =25°C, natural convection
Ta =60°C, 200LFM airflow
Over Io Range
–40° >Ta > +85°C
Over Vin range
Over Io range
Includes set-point, line, load
–40° >Ta > +85°C
Vo1 (3.3V)
Vo2 (2.5V)
Vo1 (3.3V)
Vo2 (2.5V)
Vo1
Vo2
Vo1
Vo2
Vo1
Vo2
Vo1
Vo2
Vo1
Vo2
0.1 (i)
0
0.1 (i)
0
10.8
—
—
—
—
—
—
—
—
—
—
—
8.5 (ii)
2 (ii)
8.5 (ii)
2 (ii)
—
±16
±12
±1.0
±0.5
±10
±5
±10
±10
±69
±39
84
10.5 (iii)
2.25 (iii)
10.5 (iii)
2.25 (iii)
13.2
±50
±38
—
—
±15
±7
±15
±13
—
—
—
Vo Ripple (pk-pk)
Transient Response
Vr
20MHz bandwidth
Vo1
—
35
—
Vo2
—
35
—
ttr
1A/µs load step, 50% to 100% Iotyp
—
60
—
∆Vtr
Vo over/undershoot
Vo1
—
Vo2
—
±50
—
±30
—
Notes: (i) Io1(min) current of 0.1A can be divided between both outputs, Vo1 or Vo2. The module will operate at no load with reduced specifications.
(ii) The typical current is that which can be drawn simultaneously from both outputs under the stated operating conditions.
(iii) The sum of Io1 and Io2 must be less than Io1max, and Io2 must be less than Io2max.
A
A
VDC
mV
%Vo
mV
mV
mV
%
mVpp
µs
mV
PT6982 Typical Characteristics
Efficiency vs Io1 (See Note A)
90
85
80
75
70
65
60
55
50
0
1
2
3
4
5
6
7
8
Io1 (A)
Io2 (A)
1
1.5
2
Power Dissipation vs Io1 (See Note A)
7
6
5
4
3
2
1
0
0
1
2
3
4
5
6
7
8
Io1 (A)
Io2 (A)
2
1.5
1
0.1
Vo1 Output Ripple vs Io1 (See Note A)
70
60
50
40
30
20
10
0
0
1
2
3
4
5
6
7
8
Io1 (A) [ Io2 fixed at Io2(typ) ]
Safe Operating Area, Vin =12V (See Note B)
90
80
70
Airflow
60
200LFM
120LFM
60LFM
50
Nat conv
40
30
20
0
1
2
3
4
5
6
7
8
Io1 (A) [ Io2 fixed at Io2(typ) ]
Note A: Characteristic data has been developed from actual products tested at 25°C. This data is considered typical data for the Converter.
Note B: SOA curves represent the conditions at which internal components are at or below the manufacturer’s maximum operating temperatures
For technical support and more information, see inside back cover or visit www.ti.com