absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Reverse current, IR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
Forward current, IF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mA
Package thermal impedance, θJA (see Notes 1 and 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . 149°C/W
Operating virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
TA
Operating free-air temperature
LT1004C
LT1004I
MIN MAX UNIT
0
70
°C
−40
85
electrical characteristics at specified free-air temperature
PARAMETER
TEST
CONDITIONS
LT1004-1.2
LT1004-2.5
TA‡
UNIT
MIN TYP MAX MIN TYP MAX
25°C
1.231 1.235 1.239 2.48 2.5 2.52
VZ
Reference voltage
IZ = 100 µA
Full LT1004C 1.225
range LT1004I 1.225
1.245 2.47
1.245 2.47
2.53
V
2.53
aVZ
Average
IZ = 10 µA
temperature coefficient
of reference voltage§ IZ = 20 µA
25°C
20
ppm/°C
20
Change in
∆VZ
reference voltage
with current
IZ = IZ(min) to 1 mA
IZ = 1 mA to 20 mA
25°C
Full range
25°C
Full range
1
1
1.5
1.5
mV
10
10
20
20
∆VZ/∆t
Long-term change
in reference voltage
IZ = 100 µA
25°C
20
20
ppm/khr
Minimum
IZ(min) reference current
Full range
8
10
12
20 µA
zz
Reference impedance IZ = 100 µA
25°C
Full range
0.2 0.6
1.5
0.2 0.6
Ω
1.5
Vn
Broadband
noise voltage
IZ = 100 µA,
f = 10 Hz to 10 kHz
25°C
60
120
µV
‡ Full range is 0°C to 70°C for the LT1004C and −40°C to 85°C for the LT1004I.
§ The average temperature coefficient of reference voltage is defined as the total change in reference voltage divided by the specified temperature
range.
4