English
Language : 

LMC7101_15 Datasheet, PDF (4/33 Pages) Texas Instruments – LMC7101, LMC7101Q-Q1 Tiny Low-Power Operational Amplifier With Rail-to-Rail Input and Output
LMC7101, LMC7101Q-Q1
SNOS719G – SEPTEMBER 1999 – REVISED SEPTEMBER 2015
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)(2)
Difference input voltage
Voltage at input and output pins
Supply voltage (V+ – V–)
Current at input pin
Current at output pin(3)
Current at power supply pin
Lead temperature (soldering, 10 sec.)
Junction temperature(4)
Storage temperature
MIN
MAX
±Supply Voltage
(V+) + 0.3, (V–) – 0.3
16
–5
5
–35
35
35
260
150
–65
150
UNIT
V
V
mA
mA
mA
°C
°C
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) If Military/Aerospace specified devices are required, contact the TI Sales Office or Distributors for availability and specifications.
(3) Applies to both single-supply and split-supply operation. Continuous short operation at elevated ambient temperature can result in
exceeding the maximum allowed junction temperature at 150°C.
(4) The maximum power dissipation is a function of TJ(MAX), RθJA and TA. The maximum allowable power dissipation at any ambient
temperature is PD = (TJ(MAX) – TA) / RθJA. All numbers apply for packages soldered directly into a PC board.
6.2 ESD Ratings: LMC7101
V(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-C101(2)
Machine model (MM)
VALUE
±1000
±1000
±200
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 ESD Ratings: LMC7101Q-Q1
V(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-C101
Machine model (MM)
VALUE
±1000
±1000
±200
(1) AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
UNIT
V
6.4 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted).(1)
Supply voltage, V+
Junction Temperature, TJ
LMC7101AI, LMC7101BI
LMC7101Q-Q1
MIN
MAX UNIT
2.7
15.5 V
–40
85 °C
–40
125 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
4
Submit Documentation Feedback
Copyright © 1999–2015, Texas Instruments Incorporated
Product Folder Links: LMC7101 LMC7101Q-Q1