|
CD54ACT153 Datasheet, PDF (4/11 Pages) Texas Instruments – DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS | |||
|
◁ |
CD54ACT153, CD74ACT153
DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS
SCHS339 â MARCH 2003
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
UNIT
VOH
VI = VIH or VIL
IOH = â50 µA
IOH = â24 mA
IOH = â50 mAâ
IOH = â75 mAâ
IOL = 50 µA
4.5 V
4.5 V
5.5 V
5.5 V
4.5 V
4.4
4.4
4.4
3.94
3.7
3.8
V
3.85
3.85
0.1
0.1
0.1
VOL
II
ICC
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
IOL = 24 mA
IOL = 50 mAâ
IOL = 75 mAâ
IO = 0
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
0.36
0.5
0.44
V
1.65
1.65
±0.1
±1
±1 µA
8
160
80 µA
DICCâ¡
VI = VCC â 2.1 V
4.5 V to 5.5 V
2.4
3
2.8 mA
Ci
10
10
10 pF
â Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-⦠transmission-line drive capability at 85°C and 75-⦠transmission-line drive capability at 125°C.
â¡ Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
UNIT LOAD
A or B
1
C
1
G
0.47
Unit Load is âICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
tPLH
tPHL
A or B
5.5
22 5.7
20
Y
5.5
22 5.7
20
tPLH
tPHL
Any C
4.5
18 4.6 16.4
Y
4.5
18 4.6 16.4
tPLH
G
tPHL
3.2 12.6 3.2 11.5
Y
3.2 12.6 3.2 11.5
UNIT
ns
ns
ns
operating characteristics, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
TYP UNIT
93 pF
4
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |