BQ294502 Datasheet, PDF (4/18 Pages) Texas Instruments – Overvoltage Protection for 2-Series and 3-Series Cell Li-Ion Batteries
bq294502, bq294504, bq294512, bq294515
bq294522, bq294524, bq294532, bq294562
bq294572, bq294582, bq294592
SLUSAJ3C – SEPTEMBER 2011 – REVISED MAY 2012
www.ti.com
Thermal Pad, PWRPAD
For correct operation, the power pad (PWRPAD) is connected to the VSS terminal on the printed circuit board.
FUNCTIONAL BLOCK DIAGRAM
PACK+
R VD
CVD
VDD
RIN
V3
CIN
RIN
V2
CIN
RIN
V1
CIN
VSS
VOV
OSC
PWRPAD
REG
INT_ EN
Delay
Timer
OUT
PACK–
ABSOLUTE MAXIMUM RATINGS
Over operating free-air temperature range (unless otherwise noted)(1)
PARAMETER
CONDITION
VALUE/UNIT
Supply voltage range
VDD–VSS
–0.3 to 30 V
Input voltage range
V1–VSS or V2–VSS or V3–VSS
V3–V2 or V2–V1
–0.3 to 30 V
–0.3 to 8 V
Output voltage range
OUT–VSS
–0.3 to 30 V
Continuous total power dissipation, PTOT
Functional temperature
See package dissipation rating.
–65 to 110°C
Storage temperature range, TSTG
Lead temperature (soldering, 10 s), TSOLDER
–65 to 150°C
300°C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum–rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Over operating free-air temperature range (unless otherwise noted)
PARAMETER
Supply voltage, VDD(1)
Input voltage range V3–V2 or V2–V1 or V1–VSS
Operating ambient temperature range, TA
(1) See APPLICATION SCHEMATIC.
MIN
NOM MAX UNIT
3
25
V
0
5
V
–40
110
°C
4
Submit Documentation Feedback
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Link(s): bq294502 bq294504 bq294512 bq294515 bq294522 bq294524 bq294532 bq294562