English
Language : 

BQ27350 Datasheet, PDF (4/33 Pages) Texas Instruments – Single Cell Li-Ion Battery Manager With Impedance Track Fuel Gauge Technology
bq27350
Single Cell Li-Ion Battery Manager
With Impedance Track Fuel Gauge Technology
SLUS754 – MARCH 2007
3 ELECTRICAL SPECIFICATIONS
www.ti.com
3.1 ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)
PARAMETER
VALUE
UNIT
VCC
V(IOD)
VI
TA
Tstg
Supply voltage range
Open-drain I/O pins
Input voltage range to all other pins
Operating free-air temperature range
Storage temperature range
–0.3 to 2.75
V
– 0.3 to 6
V
–0.3 to VCC + 0.3
V
–40 to 85
°C
–65 to 150
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
3.2 RECOMMENDED OPERATING CONDITIONS
TA = 25°C, VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
VCC
ICC
I(SLP)
I(HIBERNATE)
VOL
VOH
VIL
VIH
CIN
V(AI1)
V(AI2)
Supply Voltage
Normal operating mode current(1)
Low-power storage mode current(2)
Hibernate operating mode current(3)
Output voltage low (SDA, VEN)
Output high voltage (SDA)
Input voltage low (SDA, SCL)
Input voltage high (SDA, SCL)
Input capacitance
Input voltage range (CELL+, CELL–, TS)
Input voltage range (SRP, SRN)
No flash programming
Sleep mode
Hibernate mode
IOL = 0.5 mA
IOH = –1 mA
2.4
VCC–0.5
–0.3
2
VSS–0.3
VSS–0.20
2.5 2.6
150
7.4
1.5
0.4
0.8
6
5
1
0.20
(1) Load current > sleep current threshold during half of operation. Load current < sleep current threshold during other half.
(2) Low-frequency oscillator, I/O support, and IWAKE comparator circuits on.
(3) I/O support and IWAKE comparator circuits on.
UNIT
V
µA
µA
µA
V
V
V
pF
V
V
3.3 POWER-ON RESET
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; Typical Values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
VIT–
VHYS
Negative-going input voltage (VCC)
Power-on reset hysteresis
1.7
1.8
1.9
50
125
200
UNIT
V
mV
3.4 TEMPERATURE SENSOR CHARACTERISTICS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; Typical Values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
GTEMP
Temperature sensor voltage gain
–2.0
UNIT
mV/°C
4
ELECTRICAL SPECIFICATIONS
Submit Documentation Feedback