English
Language : 

BQ24618 Datasheet, PDF (4/36 Pages) Texas Instruments – Stand-Alone USB-Friendly Synchronous Switch-Mode Li-Ion or Li-Polymer Battery Charger
bq24618
SLUSA55 – OCTOBER 2010
www.ti.com
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted) (1) (2) (3)
VALUE
UNIT
VCC, ACP, ACN, SRP, SRN, BATDRV, ACDRV, CE, STAT1, STAT2, PG
–0.3 to 33
V
PH
–2 to 36
V
Voltage range
VFB
REGN, LODRV, ACSET, TS, TTC
–0.3 to 16
V
–0.3 to 7
V
BTST, HIDRV with respect to GND
–0.3 to 39
V
VREF, ISET1, ISET2
–0.3 to 3.6
V
Maximum difference
voltage
ACP–ACN, SRP–SRN
–0.5 to 0.5
V
TJ Junction temperature range
Tstg Storage temperature range
–40 to 155
°C
–55 to 155
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND if not specified. Currents are positive into, negative out of the specified terminal. Consult Packaging
Section of the data book for thermal limitations and considerations of packages.
(3) Must have a series resistor between battery pack to VFB if Battery Pack voltage is expected to be greater than 16V. Usually the resistor
divider top resistor will take care of this.
RECOMMENDED OPERATING CONDITIONS
VCC, ACP, ACN, SRP, SRN, BATDRV, ACDRV, CE, STAT1, STAT2, PG
PH
VFB
Voltage range
REGN, LODRV, ACSET, TS, TTC
BTST, HIDRV with respect to GND
ISET1, ISET2
VREF
Maximum difference
voltage
ACP–ACN, SRP–SRN
TJ Junction temperature range
Tstg Storage temperature range
VALUE
–0.3 to 28
–2 to 30
–0.3 to 14
–0.3 to 6.5
–0.3 to 34
–0.3 to 3.3
3.3
–0.2 to 0.2
0 to 125
–55 to 155
UNIT
V
V
V
V
V
V
V
V
°C
°C
4
Submit Documentation Feedback
Product Folder Link(s): bq24618
Copyright © 2010, Texas Instruments Incorporated