electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
SN54ACT16245 74ACT16245
MIN TYP MAX
MIN MAX MIN MAX
IOH = –50 mA
4.5 V 4.4
5.5 V 5.4
4.4
4.4
5.4
5.4
VOH
IOH = –24 mA
IOH = –50 mA{
IOH = –75 mA{
IOL = 50 mA
4.5 V 3.94
5.5 V 4.94
5.5 V
5.5 V
4.5 V
5.5 V
3.94
4.94
3.85
0.1
0.1
3.8
4.8
3.85
0.1
0.1
0.1
0.1
VOL
II
IOZ
ICC
∆ICCw
Control inputs
A or B ports}
IOL = 24 mA
IOL = 50 mA{
IOL = 75 mA{
VI = VCC or GND
VO = VCC or GND
VI = VCC or GND, IO = 0
One input at 3.4 V,
Other inputs at GND or VCC
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
0.36
0.5
0.44
0.36
0.5
0.44
1.65
1.65
±0.1
±1
±1
±0.5
±10
±5
8
160
80
0.9
1
1
Ci
Control inputs VI = VCC or GND
5V
4.5
Cio
A or B ports VO = VCC or GND
5V
16
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ For I/O ports, the parameter IOZ includes the input leakage current II.
§ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.
UNIT
V
V
mA
mA
mA
mA
pF
pF
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
FROM
(INPUT)
A or B
G
G
TO
(OUTPUT)
B or A
B or A
B or A
TA = 25°C
MIN TYP MAX
3.2 6.9 9.3
2.6 6.4 9.2
2.7 6.4 9.1
3.4 7.4 10.5
5.8 9.2 11.6
5.5 8.5 10.8
SN54ACT16245
MIN MAX
3.2 11.5
2.6 11.1
2.7 10.9
3.4 12.6
5.8 13.4
5.5 12.7
74ACT16245
MIN MAX
3.2 10.5
2.6 10.2
2.7
10
3.4 11.6
5.8 12.6
5.5 11.8
UNIT
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance per transceiver
Outputs enabled
Outputs disabled
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
52
pF