English
Language : 

74AC11004 Datasheet, PDF (4/5 Pages) Texas Instruments – HEX INVERTER
74AC11004
HEX INVERTER
SCAS033B – JANUARY 1988 – REVISED APRIL 1996
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
MIN TYP MAX
MIN MAX UNIT
tPLH
A
tPHL
1.5 6.1
9 1.5
10
Y
ns
1.5 5.2 7.4 1.5 8.2
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
MIN TYP MAX
MIN MAX UNIT
tPLH
A
tPHL
1.5 4.2 6.3 1.5 7.1
Y
ns
1.5 3.8 5.5 1.5
6
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance per inverter
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
29 pF
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω
Input
(see Note B)
tPHL
Output
50%
50%
VCC
0V
tPLH
50% VCC
VOH
50% VCC
VOL
LOAD CIRCUIT
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265