English
Language : 

TRS232E_10 Datasheet, PDF (3/18 Pages) Texas Instruments – DUAL RS-232 DRIVER/RECEIVER WITH IEC61000-4-2 PROTECTION
TRS232E
www.ti.com ................................................................................................................................................. SLLS791C – JUNE 2007 – REVISED SEPTEMBER 2008
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
VCC
Input supply voltage range(2)
VS+
Positive output supply voltage range
VS–
Negative output supply voltage range
VI
Input voltage range
VO
Output voltage range
Short-circuit duration
θJA
Package thermal impedance(3)(4)
TJ
Operating virtual junction temperature
Tstg
Storage temperature range
Driver
Receiver
DOUT
ROUT
DOUT
D package
DW package
N package
NS package
PW package
MIN
–0.3
VCC – 0.3
–0.3
–0.3
VS– – 0.3
–0.3
–65
MAX
6
15
–15
VCC + 0.3
±30
VS+ + 0.3
VCC + 0.3
Unlimited
73
57
67
64
108
150
150
UNIT
V
V
V
V
V
°C/W
°C
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
(3) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
VCC
Supply voltage
VIH
High-level input voltage (DIN1, DIN2)
VIL
Low-level input voltage (DIN1, DIN2)
Receiver input voltage (RIN1, RIN2)
TA
Operating free-air temperature
TRS232EC
TRS232EI
MIN NOM MAX UNIT
4.5
5 5.5 V
2
V
0.8 V
±30 V
0
70
°C
–40
85
Electrical Characteristics(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 4)
PARAMETER
TEST CONDITIONS
MIN TYP(2) MAX UNIT
ICC Supply current
VCC = 5.5 V, All outputs open, TA = 25°C
8 10 mA
(1) Test conditions are C1–C4 = 1 µF at VCC = 5 V ± 0.5 V.
(2) All typical values are at VCC = 5 V and TA = 25°C.
Copyright © 2007–2008, Texas Instruments Incorporated
Product Folder Link(s): TRS232E
Submit Documentation Feedback
3