English
Language : 

TRS202E Datasheet, PDF (3/17 Pages) Texas Instruments – 5-V DUAL RS-232 LINE DRIVER/RECEIVER WITH ±15-kV ESD PROTECTION
TRS202E
www.ti.com
SLLS847C – JULY 2007 – REVISED MAY 2010
Absolute Maximum Ratings(1) (2)
over operating free-air temperature range (unless otherwise noted)
VCC
Supply voltage range(2)
V+
Positive charge pump voltage range(2)
V–
Negative charge pump voltage range
MIN
–0.3
VCC – 0.3
–14
MAX
6
14
0.3
UNIT
V
V
V
VI
Input voltage range
Drivers
Receivers
–0.3
V+ + 0.3
V
±30
VO
DOUT
TJ
Tstg
Output voltage range
Short-circuit duration
Operating virtual junction temperature
Storage temperature range
Drivers
Receivers
V– –0.3
V+ + 0.3
V
–0.3
VCC + 0.3
Continuous
150 °C
–65
150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
Package Thermal Impedance
over operating free-air temperature range (unless otherwise noted)
qJA
Package thermal impedance(1) (2)
D package
DW package
N package
PW package
UNIT
73
57
°C/W
67
108
(1) Maximum power dissipation is a function of TJ(max), qJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/qJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(2) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions(1)
(see Figure 4)
Supply voltage
VIH
Driver high-level input voltage
VIL
Driver low-level input voltage
Driver input voltage
VI
Receiver input voltage
TA
Operating free-air temperature
(1) Test conditions are C1–C4 = 0.1 mF at VCC = 5 V ±0.5 V.
DIN
DIN
DIN
TRS202EC
TRS202EI
MIN NOM MAX UNIT
4.5
5
5.5 V
2
V
0.8 V
0
5.5
V
–30
30
0
70
°C
–40
85
Electrical Characteristics(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 4)
PARAMETER
TEST CONDITIONS
MIN TYP(2)
MAX UNIT
ICC
Suppy current
No load, VCC = 5 V
8
15 mA
(1) Test conditions are C1–C4 = 0.1 mF at VCC = 5 V + 0.5 V.
(2) All typical values are at VCC = 5 V, and TA = 25°C.
Copyright © 2007–2010, Texas Instruments Incorporated
Product Folder Link(s): TRS202E
Submit Documentation Feedback
3