English
Language : 

TRF2050 Datasheet, PDF (3/34 Pages) Texas Instruments – LOW-VOLTAGE 1.2-GHz FRACTIONAL-N/INTEGER-N SYNTHESIZER
TRF2050
LOW-VOLTAGE 1.2-GHz FRACTIONAL-N/INTEGER-N SYNTHESIZER
SLWS030D– JUNE 1996 – REVISED OCTOBER 1998
Terminal Functions
TERMINAL
NAME NO.
ÁÁÁÁÁÁÁ AUXIN
10
ÁÁÁÁÁÁÁ CLOCK
1
ÁÁÁÁÁÁÁ DATA
2
ÁÁÁÁÁÁÁ LOCK/
18
TEST
ÁÁÁÁÁÁÁ PHA
11
ÁÁÁÁÁÁÁ PHI
13
ÁÁÁÁÁÁÁ PHP
14
ÁÁÁÁÁÁÁ RFIN
5
ÁÁÁÁÁÁÁ RFIN
6
ÁÁÁÁÁÁÁ REFIN
8
ÁÁÁÁÁÁÁ RA
9
ÁÁÁÁÁÁÁ RN
16
RF
17
ÁÁÁÁÁÁÁ STROBE 3
ÁÁÁÁÁÁÁ TSETUP 19
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ VCCP
7
ÁÁÁÁÁÁÁ VDD
20
ÁÁÁÁÁÁÁ VDDA
15
ÁÁÁÁÁÁÁ VSS
4
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁ VSSA
12
I/O
I Auxiliary channel RF input
I Serial interface clock signal
I Serial interface data signal
O Lock detector/test mode output
DESCRIPTION
O Auxiliary charge pump output
O Integral charge pump output
O Proportional charge pump output
I Prescaler positive RF input
I Prescaler negative RF input
I Reference frequency input signal
I Resistor to VSSA sets auxiliary charge pump reference current
I Resistor to VSSA sets proportional and integral charge pump reference current
I Resistor to VSSA sets compensation charge pump reference current
I Serial interface strobe signal
I Test setup for pin 18. For lock detect output, pin 19 connects to VCC through a pullup resistor; for test mode output,
pin 19 terminates to ground.
Prescaler positive supply voltage
Digital supply voltage
Analog supply voltage
Digital ground
Analog ground
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCCP, VDD, VDDA (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.6 V to 5.6 V
Input voltage range, logic signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.6 V to 5.6 V
Operating ambient temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: Voltage values are with respect to VSSA.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3